Figure 274 Alarm E1 Profile
The following table describes the fields in this screen.
Table 195 Alarm E1 Profile
LABEL DESCRIPTION
The top part of the screen is for profile configuration.
Name Type a name to identify the alarm profile (you cannot change the name of the DEFVAL
profile). You can use up to 31 English keyboard characters; spaces are not allowed.
Threshold Specify limits for the individual performance counters. The system sends an alarm trap
and generates a syslog entry when one of these thresholds is exceeded. A value of 0
disables the alarm threshold.
Qes [0~900] This field sets the limit for the number of Errored Seconds that are permitted to occur
within 15 minutes.
Qses [0~900] This field sets the limit for the number of Severely Errored Seconds that are permitted to
occur within 15 minutes.
Quas [0~900] This field sets the limit for the number of UnAvailable Seconds that are permitted to occur
within 15 minutes.
Dayes [0~86400] This field sets the limit for the number of Errored Seconds that are permitted to occur
within one day.
Dayses
[0~86400]
This field sets the limit for the number of Severely Errored Seconds that are permitted to
occur within one day.
Dayuas
[0~86400]
This field sets the limit for the number of UnAvailable Seconds that are permitted to occur
within one day.
Apply Click Apply to save the changes in this screen to the system’s volatile memory. The
system loses these changes if it is turned off or loses power, so use the Config Save link
on the navigation panel and then the Save button to save your changes to the non-
volatile memory when you are done configuring.
New While you are modifying a profile, you can click New to start configuring a fresh profile
without saving your changes.
Cancel Click Cancel to start configuring the screen again.