Zyxel IES-5112 [710/1156] Command description p

Zyxel IES-5112 [710/1156] Command description p
Chapter 25 diagnostic Commands
Management Switch Card User’s Guide
710
enable <slot-gid>
<link-id>
<pattern>
Performs an IMA loopback test for the specified
IMA group.
link: the number of an E1 link in the same IMA
group
pattern: This is a 2-digit hexadecimal number
the IMA line card will add into IMA Control
Protocol (ICP) cells before sending them to the
remote connected device. The remote device
should also send ICP cells with this number to
the IMA line card. Otherwise, there is an IMA-
layer connectivity problem between these two
devices.
8
show <slot-gid>
Displays the IMA loopback testing settings for
the specified IMA group.
8
mlt test <slot-port>
all|vac|vdc|rload|
riso|cap|ren|ring|
metering|dialtone|
digit|roh [<type>
<count>] [force]
Perform the specified Metallic Line Test on the
specified VoIP line card port.
all: perform all tests
vac: test AC voltage
vdc: test DC voltage
rload: test load resistance
riso: test isolation resistance
cap: test capacitance
ren: test ringer equivalent number
ring: test ring voltage
metering: test metering voltage
dialtone: test dialtone play and the delay
digit: pulse or DTMF detection
roh: detect if the phone is on-hook or off-hook
Only all, ring and digit have <type> to
select.
With all: <type>: use 0 to perform all tests or
1 to test AC voltage, DC voltage, isolation
resistance, and capacitance.
With ring: <type>: use 0 to have the system
automatically start and stop ringing or use 1 to
manually start the ringing and 2 to manually
stop the ringing.
With digit: <type>: use 0 for automatic
testing or 1 for manual testing. With 1, use
<count> to specify how many manual inputs are
required to finish the test.
force: perform the test(s) immediately even if
the specified VoIP line card port is in use.
8
show <slot-port>
Displays the result of the Metallic Line Test last
performed on this port.
1
Table 361 diagnostic Commands (continued)
COMMAND DESCRIPTION P

Содержание

Скачать