Chapter 10 Subscriber Port Setup Screens
Management Switch Card User’s Guide
307
10.30 E1 Port Setup Screen
Click Port > E1 in the navigation panel to open the following screen. Use this screen to view and
configure an E1 port’s settings.
Figure 202 E1 Port Setup
The following table describes the fields in this screen.
SPri This field displays the IEEE 802.1p priority level for the service provider tag that the line card
adds to untagged frames that come in on this DTPVC. "0" is the lowest priority level and "7" is
the highest.
CVID This is the customer VLAN ID (the outer VLAN tag) that the line card assigns to untagged frames
received on this channel.
CPri This field displays the IEEE 802.1p priority level for the customer tag that the line card adds to
untagged frames that come in on this DTPVC. "0" is the lowest priority level and "7" is the
highest.
Select Select one or more PVCs’ check boxes and then use the Delete button to remove it (or them).
Use the Select All check box to select all of the PVCs for all of the line card’s ports.
Table 144 DTPVC Setup: Slot (continued)
LABEL DESCRIPTION
Table 145 E1 Port Setup
LABEL DESCRIPTION
E1 Port
Setup Table
This table displays the E1 port settings that are configured for the selected port.
Slot Select the number of a line card’s slot. The corresponding port setup screen for the type of line
card you selected automatically displays.
Port Select the number of an E1 port on the line card.
Load Click Load to display the port’s settings in this screen.
Enable Select this to turn this port on.