Chapter 40 Access Control
VES-1624FT-55A User’s Guide
221
40.3.1 Supported MIBs
MIBs let administrators collect statistics and monitor status and performance. The IP DSLAM
supports the following MIBs:
VDSL Line MIB(RFC-3728)
MIB II IF MIB and ADSL line MIB (RFC-2662)
SNMP MIB II (RFC-1215)
BRIDGE MIB: FDB status
RFC 3728 VDSL MIB
The IP DSLAM can also respond with specific data from the DSLAM private MIBs:
•dslam.mib
40.3.2 SNMP Traps
The IP DSLAM can send the following SNMP traps to an SNMP manager when an event
occurs. XTUC refers to the downstream channel (for traffic going from the IP DSLAM to the
subscriber). XTUR refers to the upstream channel (for traffic coming from the subscriber to
the IP DSLAM).
Table 81 SNMPv2 Traps
TRAP NAME DESCRIPTION
coldStart This trap is sent when the IP DSLAM is turned on.
warmStart This trap is sent when the IP DSLAM restarts.
linkDown This trap is sent when the Ethernet link is down. Enterprise specific
(xdslXtucLos) traps are sent when an xDSL link is down.
linkUp This trap is sent when the Ethernet or xDSL link comes up.
reboot This trap is sent when the system is going to reboot. The variable is the
reason for the system reboot.
overheat This trap is sent when the system is overheated. The variable is the
current system temperature in Celsius.
overheatOver This trap is sent when the system is no longer overheated. The
variable is the current system temperature in Celsius.
fanRpmLow This trap is sent when the RPM of the fan is too low. The variable is the
current RPM of the fan.
fanRpmNormal This trap is sent when the RPM of the fan is back within the normal
range. The variable is the current RPM of the fan.
voltageOutOfRange This trap is sent when the voltage of the system is out of the normal
range. The variable is the current voltage of the system in volts.
voltageNormal This trap is sent when the voltage of the system is back within the
normal range. The variable is the current voltage of the system in volts.
extAlarmInputTrigger This trap is sent when there is an external alarm input.
extAlarmInputRelease This trap is sent when the external alarm input stops.
thermalSensorFailure This trap is sent when the thermal sensor fails.
vdslPerfLofsThreshNotificatio
n
The number of times a Loss Of Frame has occurred within 15 minutes
for the XTUC has reached the threshold.
vdslPerfLossThreshNotificati
on
The number of times a Loss Of Signal has occurred within 15 minutes
for the XTUC has reached the threshold.