Zyxel VES-1624FT-55A [280/312] Resetting the defaults

Zyxel VES-1624FT-55A [280/312] Resetting the defaults
Chapter 53 Troubleshooting
VES-1624FT-55A User’s Guide
280
53.15 Resetting the Defaults
If you lock yourself (and others) from the IP DSLAM, you will need to reload the factory-
default configuration file. Uploading the factory-default configuration file replaces the current
configuration file with the factory-default configuration file. This means that you will lose all
previous configurations and the speed of the console port will be reset to the default of
9600bps with 8 data bit, no parity, one stop bit and flow control set to none. The user name
will be reset to “admin” and the password will be reset to “1234” and the IP address to
192.168.1.1.
53.15.1 Resetting the Defaults Via Command
If you know the password, you can reload the factory-default configuration file via Command
Line Interface (CLI) command. Use the following procedure.
1 Connect to the console port using a computer with terminal emulation software. See
chapters 2-6 for details.
2 Enter your password.
3 Type
config restore.
4 Type
y at the question “Do you want to restore default ROM file(y/n)?”
5 The IP DSLAM restarts.
The IP DSLAM is now reinitialized with a default configuration file including the default user
name of “admin” and the default password of “1234”.
3 Make sure that you have not disabled the Telnet service or changed the server port
number that the IP DSLAM uses for Telnet.
5 Ping the IP DSLAM from your computer.
If you are able to ping the IP DSLAM but are still unable to telnet, contact the distributor.
If you cannot ping the IP DSLAM, check the cable, connections and IP configuration.
Table 129 Troubleshooting Telnet (continued)
STEPS CORRECTIVE ACTION
Figure 154 Resetting the Switch Via Command
ras> config restore
System will reboot automatically after restoring default configuration.
Do you want to proceed(y/n)? >
restoring configuration...
saving configuration to flash...

Содержание