Zyxel VES-1624FT-55A [284/312] Changing the ip dslam s fuses requires partial disassembly of the device only a qualified technician should perform this process

Zyxel VES-1624FT-55A [284/312] Changing the ip dslam s fuses requires partial disassembly of the device only a qualified technician should perform this process
Chapter 54 Product Specifications
VES-1624FT-55A User’s Guide
284
Fuse Rating
1 Changing the IP DSLAM’s fuses requires partial disassembly of the device.
Only a qualified technician should perform this process.
The following table describes the location and specification of the IP DSLAM’s fuses.
ALARM Port Power
The maximum power rating for the ALARM port is as follows:
Input: 20 V, 500 mA
Output: 20 V, 500 mA
Operating Environment
Temperature: -10~60 °C
Humidity: 10% ~ 95% (non-condensing)
Storage Environment
Temperature: -40 ~ 70 °C
Humidity: 5% ~ 95% (non-condensing)
Maximum Values
Per DSL port:
Number of MAC filters: 10
Number of OUI filters: 10
Number of PVCs: 4Number of PVLAN: 8
Number of VLANs: 16
IGMP groups per DSL port: 16
IGMP host IPs per DSL port: 16
IGMP host IPs per Ethernet port: 1024
Number of DHCP snooping: 32
DHCP snooping static IP pool entries: 3
Number of joined MVLANs: 4
Number of ACL profile mappings: 8
System:
Number of user accounts: 16
Number of trap destinations: 4
Number of secured client groups: 16
Table 131 Fuse Specifications
FUSE LOCATION FUSE RATING
On AC to DC power supply 250 VAC T4A 5*20