Chapter 10 System Information
VES-1624FT-55A User’s Guide
83
Status Normal indicates that the voltage is within an acceptable operating range at this
point; otherwise Abnormal is displayed.
Fan Speed (RPM) A properly functioning fan is an essential component (along with a sufficiently
ventilated, cool operating environment) in order for the device to stay within the
temperature threshold. Each fan has a sensor that can detect and report the
fan’s RPM (Revolutions Per Minute).
Current This is the current RPM reading.
MAX This field displays the maximum RPM measured at this point.
MIN This field displays the minimum RPM measured at this point.
Average This field displays the average RPM measured at this sensor.
Threshold (Low) This field displays the lowest RPM limit at this sensor.
Threshold (Hi) This field displays the highest RPM limit at this sensor.
Status Normal indicates that the RPM is within an acceptable operating range at this
point; otherwise Abnormal is displayed.
External Alarm
Status
Name
Apply
The IP DSLAM is able to detect alarm input from other equipment connected to
the ALARM connector.
The Status column displays Normal when no alarm input has been detected
from other equipment. It displays Abnormal when alarm input has been
detected from other equipment.
Use the Name column to configure a title for each external alarm for
identification purposes. Use up to 31 characters.
Click Apply to save the name changes to the IP DSLAM’s volatile memory. The
IP DSLAM loses these changes if it is turned off or loses power, so use the
Config Save link on the navigation panel to save your changes to the non-
volatile memory when you are done configuring.
Fan Trap Mode The IP DSLAM has three fans. Select normal to have the IP DSLAM send an
SNMP trap if either one of the fans fails to function well. Select two to have the
IP DSLAM send an SNMP trap only when more than one of the fans fail.
Use this section below to configure the hardware monitor threshold settings.
New threshold
Apply
Configure new threshold settings in the fields below and click Apply to use
them.
Index This field is a sequential value.
Temperature- C (Hi) Use these fields to configure the highest temperature limit at each sensor.
Temperature- C (Lo) Use these fields to configure the lowest temperature limit at each sensor.
Volt. (Hi) Use these fields to configure the highest voltage limit at each sensor.
Volt. (Lo) Use these fields to configure the lowest voltage limit at each sensor.
Fan (Hi) Use these fields to configure the highest RPM limit at each sensor.
Fan (Low) Use these fields to configure the lowest RPM limit at each sensor.
Poll Interval(s)
Set Interval
The text box displays how often (in seconds) this screen refreshes. You may
change the refresh interval by typing a new number in the text box and then
clicking Set Interval.
Stop Click Stop to halt statistic polling.