Zyxel VES-1624FT-55A [51/312] Console port connection

Zyxel VES-1624FT-55A [51/312] Console port connection
Chapter 3 Front Panel Connections
VES-1624FT-55A User’s Guide
51
Figure 14 Removing the Transceiver
3.4 Console Port Connection
For local management, you can use a computer with terminal emulation software configured
to the following parameters:
VT100 terminal emulation
9600 bps
No parity, 8 data bits, 1 stop bit
No flow control
Connect the mini-RJ-11 male end of the console cable to the console port of the IP DSLAM.
Connect the female end to a serial port (COM1, COM2 or other COM port) of your computer.
3.5 ALARM Connection
A closed circuit on the ALARM input pins indicates an alarm. Pins 7 and 3 are alarm input
one. Pins 8 and 4 are alarm input two. Pins 8 and 5 are alarm input 3. Pins 9 and 8 are alarm
input 4.
The IP DSLAM signals an alarm when it detects an alarm on the ALARM input pins or the IP
DSLAM.
To signal an alarm, the IP DSLAM opens the circuit for pins 1 and 6 (the common pin) and
closes the circuit for pins 2 and 6.
Examples of an alarm on the IP DSLAM are when the IP DSLAM’s voltage or temperature is
outside of the normal range.
Figure 15 ALARM Pins Layout
Pin 1
Pin 6
Pin 5
Pin 9