Moxa PT-7528-20MSC-4TX-4GSFP-HV-HV [16/116] Redundancy

Moxa PT-7528-12MST-12TX-4GSFP-WV-WV [16/116] Redundancy
PT-7528 Series Quick Settings
3-4
Redundancy
The Moxa switch uses an IP address-based filtering method to control access.
Redundancy Protocol
Setting Description Factory Default
None Ring redundancy is not active. None
RSTP Select this item to change to the RSTP configuration page.
Turbo Ring V2 Select this item to change to the Turbo Ring V2 configuration
page.
Redundant Port
Setting Description Factory Default
1
st
Port Select any port of the switch to be one of the redundant ports.
15, 16
2
nd
Port Select any port of the switch to be one of the redundant ports.
You can set other redundancy protocols, such as Turbo Ring V1/Turbo Chain/MSTP, in advanced setting section.
More details please refer to “Communication Redundancy User’s Manual”.
VLAN
To configure 802.1Q VLAN and port-based VLANs on the Moxa switch, use the VLAN Settings page to
configure the ports.
VLAN Mode
Setting Description Factory Default
802.1Q VLAN Set VLAN mode to 802.1Q VLAN 802.1Q VLAN
Unaware VLAN Set VLAN mode to Unaware VLAN