Moxa PM-7200-6MSC [147/155] Turbo ring v2 coupling primary

Moxa PT-508-SS-LC-24 [147/155] Turbo ring v2 coupling primary
Moxa Command Line Interface (FW_4.x) Commands
2-138
Command
Modes
Redundancy configuration
Usage
Guidelines
At least enable one turbo-ring domain or coupling. But cannot enable two turbo-
ring domains
and coupling in the same time.
Examples
PT-7828(config-rdnt)# turbo-ring-v2 coupling dual-homing primary interface 2/1
secondary interface 2/2
<STRING:pri_port> - Port ID. E.g., 1/3, Trk2,...
<STRING:sec_port> - Port ID. E.g., 1/3, Trk2,...
Error
messages
Turbo ring v2 only supports maximum 2 ring domains
Ring1: One port couldn’t be set as 1st and 2nd redundant port simultaneously !!!
Ring2: One port couldn’t be set as Ring1 redundant port simultaneously !!!
Coupling: One port couldn’t be set as 1st and 2nd redundant port simultaneously !!!
Primary port couldn’t be set as Ring2 redundant port simultaneously !!!
Backup port couldn’t be set as Ring2 redundant port simultaneously !!!
Coupling port couldn’t be set as Ring2 redundant port simultaneously !!!
Please select at least one Ring!!!
Ring1, ring2, coupling couldn’t be enabled simultaneously!!!
Please enable one Ring in “Ring Coupling” mode!!!
Related
commands
show turbo-ring-v2
turbo-ring-v2 coupling primary
Use the turbo-ring-v2 coupling primary redundancy configuration command on the switch to configure the
primary port of Ring coupling for Turbo Ring v2. Use the no form of this command to return to the default
setting.
Commands
turbo-ring-v2 coupling primary interface primary-port
no turbo-ring-v2 coupling
Syntax
Description
turbo-ring-v2 Configure turbo ring v2
coupling Configure ring coupling
primary Configure ring coupling mode
interface Turbo ring v2 coupling ports setting
primary-port Port ID. E.g., 1/3, 2/1,...
Defaults N/A
Command
Modes
Redundancy configuration
Usage
Guidelines
At least enable one turbo-ring domain or coupling. But cannot enable two turbo-
ring domains
and coupling in the same time.
Examples
PT-7828(config-rdnt)# turbo-ring-v2 coupling primary interface 2/1
<STRING:pri_port> - Port ID. E.g., 1/3, Trk2,...
Error
messages
Turbo ring v2 only supports maximum 2 ring domains
Ring1: One port couldn’t be set as 1st and 2nd redundant port simultaneously !!!
Ring2: One port couldn’t be set as Ring1 redundant port simultaneously !!!
Coupling: One port couldn’t be set as 1st and 2nd redundant port simultaneously !!!
Primary port couldn’t be set as Ring2 redundant port simultaneously !!!
Backup port couldn’t be set as Ring2 redundant port simultaneously !!!
Coupling port couldn’t be set as Ring2 redundant port simultaneously !!!
Please select at least one Ring!!!
Ring1, ring2, coupling couldn’t be enabled simultaneously!!!
Please enable one Ring in “Ring Coupling” mode!!!