Moxa PM-7200-6MSC [18/155] Clock summer time

Moxa PT-510-3S-SC-24 [18/155] Clock summer time
Moxa Command Line Interface (FW_4.x) Commands
2-9
month 1 to 12
day 1 to 31
year 2000 to 2037
Defaults N/A
Command
Modes
Global configuration
Usage
Guidelines
N/A
Examples
PT-7828(config)# clock set 11:11:11 1 1 2010
Error
messages
Illegal parameters!
Related
commands
show clock
clock summer-time
Use the clock summer-time global configuration command on the switch to enable the daylight saving time
offset and set the apply duration. Use the no form of this command to disable it.
Commands
clock summer-time start-date month week day hour
clock summer-time end-date month week day hour
clock summer-time offset offset-hour
Syntax
Description
clock Configure time-of-day clock
summer-time Configure Summer time parameter
start-date The date when summer time offset start
end-date The date when summer time offset end
month From ‘Jan’, ‘January’ or ‘1’ to ‘Dec’, ‘December’, or ‘12’
week From ‘1st’ or ‘1’ to ‘Last’ or ‘6’
day From ‘Sun’, ‘Sunday’ or ‘1’ to ‘Sat’, ‘Saturday’ or ‘7’
hour 0 to 23
offset Summer time offset
offset-hour 1 to 12
Defaults N/A
Command
Modes
Global configuration
Usage
Guidelines
When configuring the summer time offset, the start-date and end-date must be configured
correctly first.
Examples
PT-7828(config)# clock timezon gmt -4
Error
messages
Invalid parameter
Month must be configured as ‘Jan’, ‘January’ or a numerical ‘1’.
Week must be configured as ‘1st’, ‘2nd’, ‘3rd’, ‘4th’, ‘5th’ or ‘Last’
Day must be configured as ‘Sun’, ‘Sunday’ or a numerical ‘1’.
Hour must be in the range from 0 to 23.
Please input the correct start/end date of the summer time first!