Moxa Command Line Interface (FW_4.x) Commands
2-145
Command
Modes
Global configuration
Usage
Guidelines
action-index as follow,
Trap only(1), Email only(2), Trap+Email(3), Syslog only(4), Trap+Syslog(5),
Email+Syslog(6), Trap+Email+Syslog(7), Relay1 only(8), Trap+Relay1(9),
Email+Relay1(10), Trap+Email+Relay1(11), Syslog+Relay1(12),
Trap+Syslog+Relay1(13), Email+Syslog+Relay1(14),
Trap+Email+Syslog+Relay1(15), Relay2 only(16), Trap+Relay2(17),
Email+Relay2(18), Trap+Email+Relay2(19), Syslog+Relay2(20),
Trap+Syslog+Relay2(21), Email+Syslog+Relay2(22),
Trap+Email+Syslog+Relay2(23), Relay1+Relay2(24), Trap+Relay1+Relay2(25),
Syslog+Relay1+Realy2(28), Email+Syslog+Relay1+Relay2(30),
Trap+Email+Syslog+Relay1+Relay2(31), None(0)
severity-level as follow,
Emergency(0), Alert(1), Critical(2), Error(3), Warning(4), Notice(5), Information(6),
Debug(7)
Examples
EDS-G516E(config)# warning-notification system-event cold-start action 5
EDS-G516E(config)# warning-notification system-event cold-start severity 3
EDS-G516E(config)# no warning-notification system-event cold-start active
Error
messages
Invalid action value or non-support this combination action
Invalid severity type
Related
commands
show relay-warning config
warning-notification port-event
Use warning-notification port-event interface configuration commands to enable the port warning events trigger to
email, relay, syslog or trap. Use no form of this command to disable it.
Commands
warning-notification port-event {event { link-on | link-off | traffic-overload rx-threshold duration} | action
action-index |severity severity-level | active}
no warning-notification port-event {event { link-on | link-off | traffic-overload} | active}
Syntax
Description
warning-notification
port-event
event
link-on
link-off
traffic-overload
rx-threshold
duration
action
action-index
severity
severity-level
active