Moxa PM-7200-6MSC [59/155] Ptp arb time

Moxa PT-510-SS-SC-48 [59/155] Ptp arb time
Moxa Command Line Interface (FW_4.x) Commands
2-50
Error
messages
announceReceiptTimeout must be in the range from 2 to 10
Related
commands
Show ptp settings
Show ptp status
Show ptp port
ptp arb-time
Use the ptp arb-time configuration command on the switch to set the arb-time parameter of the local clock.
Commands
ptp arb-time time
Syntax
Description
ptp Configure PTP
arb-time Set the ARB time parameter of the local clock
time 0 to 2147483646
Defaults default is 0
Command
Modes
configuration
Usage
Guidelines
N/A
Examples
PT-7828(config)# ptp arb-time 0
Error
messages
Arb time must be in the range from 0 to 2147483646
Related
commands
Show ptp settings
Show ptp status
Show ptp port
ptp clockclass
Use the ptp clockclass configuration command on the switch to set the clockclass parameter of the local clock.
Commands
ptp clockclass class
Syntax
Description
ptp Configure PTP
clockclass Set the clock class parameter of the local clock
class 0 to 255
Defaults default is 248
Command
Modes
configuration
Usage
Guidelines
N/A
Examples
PT-7828(config)# ptp clockclass 248
Error
messages
clockclass must be in the range from 0 to 255
Related
commands
Show ptp settings
Show ptp status
Show ptp port

Содержание

Похожие устройства

Скачать