Moxa DA-682A-C7-DPP [15/45] Wiring requirements

Moxa DA-682A-C7-DPP-LX [15/45] Wiring requirements
DA-682A-DPP Hardware Hardware Installation
2-4
Use two screws on the left side and two screws on the right side. Check to make sure that the four screws are
firmly attached to the rack.
Wiring Requirements
The following common safety precautions should be observed before installing any electronic device:
Keep power wires and communications/signals wires in separate paths. If power and
communications/signal wires must cross paths, make sure the wires are perpendicular at the intersection
point.
Use the type of signal transmitted through a wire to determine which wires should be bundled together and
which kept separate. The rule of thumb is that wiring that carries similar electrical signals can be bundled
together.
We strongly recommend that you label the wiring for all devices in the system for easy identification.
ATTENTION
Do not run signal or communication wiring and power wiring in the same wire conduit. To avoid interference,
wires with different signal characteristics should be routed separately.
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring
your device.
Electrical Current
Caution!
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes
dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings,
the wiring could overheat, causing s
erious damage to your equipment.
Temperature Caution!
Be
careful when handling the unit. When the unit is
plugged in, the internal components generate heat, and
consequently the
outer casing may feel hot to the touch.