Lainox CEV026S+LD25 [31/50] Mc cal hc cal if present

Lainox CEV026S+LD25 [31/50] Mc cal hc cal if present
31
SPECIAL PROGRAMS
23 MC CAL - HC CAL (if present)
Press Recipe button 6,
[ACC] appears on display 7. Turn the knob 8
to the left until you see [SPC] and press the
knob 8 to confirm.
Turn the knob 8 until you see [MC CAL] or
[HC CAL] on display 7 and 9 and press button
15.
T
he display shows [rAF] if the oven
temperature is high, [Att] if the oven
temperature is too low.
ATTENTION: Make sure the Limescale
removal connector is firmly attached and that
there is sufficient Limescale removal liquid in
the can.
USE ONLY THE “CALFREE” LIMESCALE
REMOVAL PRODUCT SUPPLIED BY THE
PRODUCER.
The program ends when you see [End] on
display 9. Press button 6 to exit the program.
6
15
7
8
9
23.1 EXECUTING
THE MC CAL or HC CAL
Foreword
Iftheovenoffersautomaticcleaning(onrequest),youcanchoosetoexecutetheCALOUT limescale
removal cycle together with the MEDIUM or HARD automatic cleaning cycle ([MC CAL] or [HC
CAL] cycle)
90026410rev01