Zanussi ZGL646ITX [23/88] By pass diameters

Zanussi ZGL646ITX [23/88] By pass diameters
Appliance class: 3
By-pass diameters
Burner Ø By-pass in 1/100 mm.
Auxiliary 28
Burner Ø By-pass in 1/100 mm.
Semi-rapid 32
Rapid 42
Gas burners
BURNER
NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 20 mbar
LPG
(Butane/Propane) G30/G31 (3B/P) 30/30
mbar
kW kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
G30 G31
g/h g/h
Auxiliary
burner
1.0 0.33 70 0.095 50 73 71
Semi-rapid
burner
2.0 0.45 96 0.190 71 145 143
Rapid burn-
er
3.0 (natural
gas)
2.8 (LPG)
0.75 119 0.285 86 204 200
Gas burners G20 13 mbar - only Russia
BURNER NORMAL
POWER
REDUCED POWER NORMAL POWER
NATURAL GAS
G20 (2H) 13 mbar
kW kW inj. 1/100 mm m³/h
Auxiliary burner 0.9 0.33 80 0.095
Semi-rapid burner 1.4 0.45 105 0.148
Rapid burner 1.9 0.75 120 0.201
Environment concerns
The symbol on the product or on its packaging
indicates that this product may not be treated as
household waste. Instead it should be taken to the
appropriate collection point for the recycling of electrical
and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential
negative consequences for the environment and human
health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed
information about recycling of this product, please contact
your local council, your household waste disposal service
or the shop where you purchased the product.
23

Содержание

Скачать