Qtech QSW-2910-09T-POE-AC/DC [43/212] Interface shutdown control configuration list

Qtech QSW-2910-09T-POE-AC/DC [43/212] Interface shutdown control configuration list
+7(495) 797-3311 www.qtech.ru
Москва, Новозаводская ул., 18, стр. 1
43
the interface will be shut down and failure trap will be sent. After a while(it is defaulted to be
480 seconds, which can be configured), it may reopen. If the interface will not reshutdown-
control in 2 seconds, it turns normal and normal trap will be sent. If the interface reshutdown-
control in 2 seconds, the failure trap will not be sent.
2.7.2 Interface shutdown-control Configuration list
Interface shutdown-control Configuration list is as following:
shutdown-control Configuration
Configure shutdown-control open-time
Display shutdown-control
Recover shutdown-control
2.7.3 shutdown-control Configuration
Configure it in interface configuration mode:
Enable shutdown-control
shutdown-control [ broadcast | multicast | unicast ] target-rate
Disable shutdown-control
no shutdown-control [ broadcast | multicast | unicast ]
By default, shutdown-control is disabled.
Example:
!Enable shutdown-control of e0/8 for broadcast and speed rate is
100pps.
QTECH(config-if-ethernet-0/8)#shutdown-control broadcast 100
2.7.4 Configure shutdown-control open-time
Configure it in global configuration mode:
Configure shutdown-control open-time
shutdown-control-open-time
The default shutdown-control open-time is 480 seconds.
Example:
!Configure shutdown-control-open-time of CAR is 20 seconds
QTECH(config)# shutdown-control-open-time 20