Qtech QSW-2910-09T-POE-AC/DC [59/212] Brief introduction of vprb

Qtech QSW-2910-09T-POE-AC/DC [59/212] Brief introduction of vprb
+7(495) 797-3311 www.qtech.ru
Москва, Новозаводская ул., 18, стр. 1
59
3.10 VPRB
3.10.1 Brief introduction of VPRB
VPRB (vlan port redundancy backup) is for vlan port backup. If there are multiple ports in a
vlan, one of them can be specified to be a major-port, another is the backup port for the major-
port. Generally, if major and backup-ports work normal, major-port is forwarding and backup-
port is discarding, and all business packets will be sent by major-port. If major-port works
abnormal and unable to forward packets, the backup-port will turn forwarding immediately and
start sending business packets until the major-port works normal.
In order to achieve backup and load balance in batch, VPRB needs to work with MSTP. First,
add backup vlan to MSTP instance, then configure the major-port and backup-port of this
MSTP instance.
3.10.2 VPRB configuration list
Configure/delete VPRB port backup
Show VPRB
3.10.3 Configure/delete VPRB port backup
Configure it in global configuration mode:
Configure VPRB port backup
vprb major-port ethernet port-id bak-port ethernet port-id instance inst-id
Delete VPRB port backup
no vprb major-port ethernet port-id
Parameter:
port-id: major-port or backup port
inst-id: MSTP instance id
Example:
!Add vlan 1-10 to MSTP instance 1
QTECH(config)#spanning-tree mst instance 1 vlan 1-10
!Specify major-port is e0/1, backup port is e0/2
QTECH(config)#vprb major-port ethernet 0/1 bak-port ethernet 0/2
instance 1
3.10.4 Show VPRB
Configure it in any mode:
show vprb