Daikin EWADC14BJYNN [31/346] Esie07 04 general outline

Daikin EWADC11BJYNN [31/346] Esie07 04 general outline
ESIE07-04 General Outline
Part 1 – System Outline 1–19
3
1
4
5
Note: (1) Cooling capacity and power input are based on 12/7°C entering/leaving water temp. and 35°C air ambient
temp.
Power input is for compressor only.
Note: (1) Cooling capacity and power input are based on 12/7 °C entering/leaving water temp. and 35°C air ambient
temp.
Power input is for compressor only.
Weight and dimensions
Standard unit shipping weight kg 6803 8780 8780 9310 9310 9750 9900
Standard unit operating weight kg 7207 9190 9190 9720 9720 10160 10310
Unit length mm 8300 9200 9200 10100 10100 11000 11000
Unit width mm 2230 2230 2230 2230 2230 2230 2230
Unit height mm 2520 2520 2520 2520 2520 2520 2520
Model EWAD-BJYNN/A with OPLN
Unit size C10 C11 C12 C13 C14 C15 C16
Model EWAD-BJYNN/A with OPLN
Unit size C17 C18 C19 C20 C21
Cooling capacity (1) kW 1401 1512 1618 1762 1871
Power input (1) kW 408 501 541 572 594
COP 3.44 3.02 2.99 3.08 3.15
Screw compressors 3 4 4 4 4
Refrigerant circuits 3 4 4 4 4
Refrigerant charge R-134a kg 232 256 264 264 264
Oil charge kg 60 80 80 80 80
Min % of capacity reduction % 8.3 6.25 6.25 6.25 6,25
Condenser fans
No. of fans / nominal power fan kW 26/1 26/1 28/1 28/1 28/1
Fan speed rpm 680 680 680 680 680
Diameter mm 800 800 800 800 800
Total air flow m3/s 106.3 105.2 113.3 114.4 114.4
Evaporator
Evaporators / water volume N°/l 1/533 2/254+246 2/246+246 2/246+246 2/392+392
Max operating pressure bar 10.5 10.5 10.5 10.5 10.5
Water connection diameter mm 219.1 168.3 168.3 168.3 219.1
Condenser coil
Coil type Lanced fins - internally spiral wound tubes
Weight and dimensions
Standard unit shipping weight kg 10715 11440 11648 11848 12624
Standard unit operating weight kg 11291 11900 12158 12358 13516
Unit length mm 12800 12800 13670 13670 13670
Unit width mm 2230 2230 2230 2230 2230
Unit height mm 2520 2520 2520 2520 2520