Daikin FXDQ32PVET [392/394] Drawings flow charts

Daikin FXDQ20PVET [392/394] Drawings flow charts
Si34-704
Drawings & Flow Charts v
Drawings & Flow Charts
A
Abnormal Discharge Pipe Temperature
...............229
Abnormal Outdoor Fan Motor Signal
...................232
Actuation of High Pressure Switch
.......................217
Actuation of Low Pressure Sensor
.......................219
Address Duplication of Centralized Controller
.....286
Address Duplication, Improper Setting
.................297
C
Centralized Control Group No. Setting
.................153
BRC1A Type
..................................................153
BRC4C Type
.................................................154
BRC7C Type
.................................................154
BRC7E Type
..................................................154
Group No. Setting Example
...........................154
Check No. 1
.........................................................304
Check No. 2
.........................................................304
Check Operation not Executed
............................270
Compressor Motor Overcurrent/Lock
...................223
Contents of Control Modes
..................................155
How to Select Operation Mode
......................156
Control of Outdoor Air Processing Unit (Unique
Control for Outdoor Air Processing Unit)
......124
Discharge Air Temperature Control
...............125
Selection of Operation Mode
(by suction air thermostat)
................124
Current Sensor Malfunction
.................................235
D
Defective Inverter PCB
........................................247
Display “Under Centralized Control” Blinks
(Repeats Double Blink)
.................................303
Display “Under Centralized Control” Blinks
(Repeats Single Blink)
..................................300
Display of sensor and address data
.....................189
Drain Level above Limit
.......................................209
Drain Pump Control
.............................................116
When the Float Switch is Tripped and “AF” is
Displayed on the Remote
Controller
..........................................117
When the Float Switch is Tripped while the
Cooling Thermostat is OFF ...............116
When the Float Switch is Tripped While the
Cooling Thermostat is ON
................116
E
Electronic Expansion Valve Malfunction /
Dust Clogging
...............................................205
Error of External Protection Device
......................198
Example of connection (R-410A Type)
................359
F
Fan Motor (M1F) Lock, Overload
........................ 202
Faulty Field Setting after Replacing Main PC Board
or Faulty Combination of PC Board
............. 263
Field Setting from Outdoor Unit
........................... 157
Mode changing procedure
............................ 161
Setting by dip switches
................................. 159
Freeze Prevention
............................................... 122
Functional Parts Layout
........................................ 69
G
Gas Shortage Alert
.............................................. 264
I
Improper Combination of Indoor and Outdoor Units,
Indoor Units and Remote Controller
............ 283
Improper Combination of Optional Controllers for
Centralized Control
...................................... 295
Inverter Compressor Motor Lock
......................... 221
Inverter Compressor Starting Failure
.................. 254
Inverter Over-Ripple Protection
........................... 260
L
Louver Control for Preventing Ceiling Dirt
........... 118
M
Malfunction of Capacity Determination Device
... 210
Malfunction of Discharge Pipe Thermistor
(R3, R31, 32T)
............................................. 236
Malfunction of Drain Level Control System
(S1L)
............................................................ 200
Malfunction of Electronic Expansion
Valve Coil
..................................................... 207
Malfunction of High Pressure Sensor
.................. 243
Malfunction of Inverter Radiating Fin
Temperature Rise
........................................ 248
Malfunction of Inverter Radiating Fin
Temperature Rise Sensor
............................ 261
Malfunction of Liquid Pipe Thermistor 1
(R6T)
............................................................ 240
Malfunction of Low Pressure Sensor
.................. 245
Malfunction of Moving Part of Electronic Expansion
Valve (Y1E, Y2E)
......................................... 227
Malfunction of Outdoor Unit Fan Motor
............... 224
Malfunction of Subcooling Heat Exchanger Gas Pipe
Thermistor (R5T)
.......................................... 242
Malfunction of Swing Flap Motor (M1S)
.............. 203
Malfunction of System, Refrigerant System Address
Undefined
..................................................... 291
Malfunction of Thermistor (R1T) for
Outdoor Air
................................................... 234
Malfunction of Thermistor (R1T) for
Suction Air
.................................................... 213
Malfunction of Thermistor (R2T) for
Heat Exchanger
........................................... 211

Содержание

Скачать