Table of Contents iii
3.10 C1” Indoor Unit: Failure of Transmission
(Between Indoor unit PC Board and Fan PC Board)............................154
3.11 C4” Indoor Unit: Malfunction of Thermistor (R2T)
for Heat Exchanger ..............................................................................156
3.12 C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes .........157
3.13 C6” Indoor Unit: Failure of Combination
(Between Indoor unit PC Board and Fan PC Board)............................158
3.14 C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........159
3.15 CA” Indoor Unit: Malfunction of Thermistor for Discharge Air...............160
3.16 CC” Indoor Unit: Malfunction of Humidity Sensor System ....................161
3.17 CJ” Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller ................................................................................162
3.18 E1” Outdoor Unit: PC Board Defect .....................................................163
3.19 E3” Outdoor Unit: Actuation of High Pressure Switch..........................164
3.20 E4” Outdoor Unit: Actuation of Low Pressure Sensor..........................166
3.21 E5 Inverter Compressor Motor Lock ...................................................168
3.22 E7 Malfunction of Outdoor Unit Fan Motor .........................................169
3.23 E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y3E)...............................................170
3.24 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature..................172
3.25 F6 Outdoor Unit: Refrigerant Overcharged.........................................173
3.26 H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....174
3.27 J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor (R2T) ....175
3.28 J5” Outdoor Unit: Malfunction of Thermistor (R3T, R5T) for
Suction Pipe 1, 2 ..................................................................................176
3.29 J6” Outdoor Unit: Malfunction of Thermistor (R6T) .............................177
3.30 J7” Outdoor Unit: Malfunction of Thermistor (R7T) for
Outdoor Unit Liquid Pipe ......................................................................178
3.31 J9” Outdoor Unit: Malfunction of Thermistor (R4T) .............................179
3.32 JA” Outdoor Unit: Malfunction of High Pressure Sensor......................180
3.33 JC” Outdoor Unit: Malfunction of Low Pressure Sensor ......................181
3.34 L1” Outdoor Unit: Malfunction of PC Board .........................................182
3.35 L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................183
3.36 L5” Outdoor Unit: Inverter Compressor Abnormal ...............................184
3.37 L8” Outdoor Unit: Inverter Current Abnormal.......................................185
3.38 L9” Outdoor Unit: Inverter Start up Error .............................................186
3.39 LC” Outdoor Unit: Malfunction of Transmission between
Inverter and Control PC Board.............................................................187
3.40 P1” Outdoor Unit: High Voltage of Capacitor in
Main Inverter Circuit .............................................................................188
3.41 U0Low Pressure Drop Due to Refrigerant Shortage or
Electronic Expansion Valve Failure......................................................189
3.42 U2Power Supply Insufficient or Instantaneous Failure ......................191
3.43 U3 Check Operation not Executed......................................................193
3.44 U4 Malfunction of Transmission between Indoor Units and
Outdoor Units .......................................................................................194
3.45 U5 Malfunction of Transmission between Remote Controller and
Indoor Unit............................................................................................196
3.46 U8 Malfunction of Transmission between Main and
Sub Remote Controllers .......................................................................197
3.47 U9Malfunction of Transmission between Indoor and
Outdoor Units in the Same System ......................................................198