Icom IC-Q7A [7/43] Panel description
![Icom IC-Q7A [7/43] Panel description](/views2/1074437/page7/bg7.png)
3
2
PANEL DESCRIPTION
y VOLUME CONTROL SWITCHES [VOLY]/[VOLZ]
➥Push to adjust the audio level. (p. 10)
➥Push [FUNC] + either switch to start a scan. (p.16)
➥Push [FUNC] + either switch for 2 sec. to start a tone
scan. (p.27)
u VFO/MEMORY SWITCH [V/M]
➥Toggles between VFO and memory modes. (p. 6)
➥Enters set mode when pushed for 2 sec.(p. 28)
➥Push [FUNC] + [V/M] to enter memory write mode. (p.
12)
➥Push [FUNC] + [V/M] for 2 sec. to write the operating fre-
quency into the selected memory channel in VFO mode.
(p. 13)
➥Push [FUNC] + [V/M] for 2 sec.to write the displayed fre-
quency into the VFO in memory mode. (p. 13)
i POWER SWITCH [POWER]
Push for 2 sec. to toggle the transceiver power ON and
OFF.
o MONITOR SWITCH [SQL] (p. 10)
➥Push and hold to temporarily open the squelch and
monitor the operating frequency. (default behaviour)
➥While pushing, rotate the tuning dial to set the squelch
threshold level.
➥Push [FUNC] + [SQL] to exchange the receive/transmit
frequency and duplex direction when the duplex function
is in use.
!0 CALL/LOCK SWITCH [CALL(LOCK)]
➥Selects the call channel. (p. 14)
➥Push [FUNC] + [CALL] to toggle the lock function ON
and OFF. (p.8)
➥While in the memory channel programming condition,
push [FUNC] + [CALL] for 2 sec. to clear the contents.
(p. 14)
➥Generates a 1750 Hz tone for repeater access while
transmitting. (Europe and Italy versions only; p. 24)
!1 EXTERNAL SPEAKER AND MICROPHONE JACK
[SP/MIC]
Connects an optional speaker-microphone or headset via
an optional OPC-782
PLUG ADAPTER CABLE, if desired.
The internal microphone and speaker will not function
when the OPC-782 is connected. (See p. 38 for a list of
available options.)
!2 TUNING DIAL [DIAL]
➥Rotate [DIAL] to set operating frequencies, memory
channels, set mode contents, etc. (p. 7)
➥While pushing [SQL], sets the squelch level. (p. 10)
➥While pushing [FUNC], sets the operating frequency in
100 kHz, 1 MHz or 10 MHz steps in VFO mode.(pgs.7,
29)
➥While pushing [FUNC], sets the operating channel in 10
channel steps in memory mode. (pgs. 7, 8)
Содержание
- Dual band fm transceiver 1
- Instruction manual 1
- Iq7a iq7e 1
- Cautions 2
- Do not 2
- Explicit definitions 2
- Foreword 2
- R warning neve 2
- Read all instruction 2
- Save this instruction manual 2
- Caution 3
- Supplied accessories 3
- Table of contents 4
- Accessory attachment 5
- Caution 5
- D antenna 5
- D battery installation 5
- D belt clip 5
- D handstrap 5
- I panel description 6
- Panel description 6
- Panel description 7
- I function display 8
- Panel description 8
- Panel description 9
- Frequency and channel setting 10
- I operating band selection 10
- Vfo and memory call channels 10
- D using set mode 11
- D using the band switch 11
- Frequency and channel setting 11
- I setting a frequency 11
- I setting a tuning step 11
- Frequency and channel setting 12
- I lock function 12
- I rit function 12
- I selecting a memory channel 12
- Basic operation 13
- Caution 13
- I receiving and transmitting 13
- Basic operation 14
- I monitor function 14
- I setting squelch level 14
- I setting volume level 14
- Basic operation 15
- D setting the backlighting setting 15
- D setting the receive mode 15
- I display backlighting 15
- I receive mode selection 15
- I general 16
- Memory call channels 16
- Programming during selection 16
- I programming after selection 17
- I transferring memory contents to another memory 17
- Memory call channels 17
- D programming a call channel 18
- D selecting a call channel 18
- I call channel 18
- I memory clear 18
- Memory call channels 18
- I scan types 19
- Scan operation 19
- D memory bank selection 20
- I full band programmed scan 20
- I memory bank scan 20
- Scan operation 20
- I selecting scan edges 21
- Scan operation 21
- D setting the scan pause time 22
- D setting the scan resume time 22
- I scan resume condition 22
- I skip channel setting 22
- Scan operation 22
- D frequency skip function on off 23
- D programming a skip frequency 23
- I frequency skip function 23
- Scan operation 23
- I priority watch types 24
- Priority watch 24
- D memory call channel watch and memory scan watch 25
- D vfo scan watch 25
- I priority watch operation 25
- Priority watch 25
- D setting duplex and duplex direction 26
- I general 26
- Repeater operation 26
- Available subaudible tone frequencies unit hz 27
- D setting the subaudible tone frequency 27
- D turning the subaudible tone encoder on off 27
- E while pushing func rotate dial to select tone r push v m to exit set mode 27
- Each operating band and each memory channel have inde pendent settings 27
- I subaudible repeater tones 27
- Q push v m for 2 sec to enter set mode w rotate dial until t tsql appears 27
- Q select vfo mode or desired memory channel to be pro grammed w push v m for 2 sec to enter set mode e rotate dial until r tone repeater tone appears 27
- R while pushing func rotate dial to select the desired subaudible tone 27
- Repeater operation 27
- Some repeaters require subaudible tones to be accessed subaudible tones are superimposed over your normal signal and must be set in advance 27
- T push v m to exit set mode 27
- Europe and italy versions only 28
- I 1750 hz tone 28
- I offset frequency 28
- Repeater operation 28
- D frequency range and offset direction 29
- I auto repeater function 29
- Repeater operation 29
- U s a version only 29
- D operation 30
- D setting subaudible tones for tone squelch operation ctcss tones 30
- I tone squelch operation 30
- Subaudible tone operation 30
- D calling a waiting station using pocket beep 31
- D waiting for a call from a specific station 31
- I pocket beep operation 31
- I tone scan 31
- Subaudible tone operation 31
- D expanded set mode on off 32
- D set mode items 32
- I set mode 32
- Other functions 32
- D setting dial select step 33
- I beep tones 33
- I dial select step 33
- I power saver 33
- Other functions 33
- I auto power off function 34
- I monitor switch function 34
- Other functions 34
- I dial speed acceleration 35
- I lock function effect 35
- Other functions 35
- Caution 36
- I all reset 36
- I channel indication mode 36
- I partial reset 36
- Other functions 36
- If your transceiver seems to be malfunctioning please check the following points before sending it to a service center 37
- Problem possible cause solution ref 37
- Troubleshooting 37
- Call channel mode 38
- Displays for set and expanded set modes show the default settings except the expanded set mode setting 38
- Memory mode 38
- Operation flow chart 38
- Rotate dial while pushing func to change the set mode condition 38
- Vfo mode 38
- Operation flow chart 39
- Set mode expanded set mode 39
- D general 40
- D transmitter 40
- Specifications 40
- D receiver 41
- Specifications 41
- Options 42
- 9 16 kamihigashi hirano ku osaka 547 0002 japan 43
- Count on us 43
Похожие устройства
- Panasonic DMC-GF5KEE-K Инструкция по эксплуатации
- Icom IC-T2H Инструкция по эксплуатации
- Panasonic DMC-GF5KEE-R Red Инструкция по эксплуатации
- Icom IC-T7H Инструкция по эксплуатации
- Panasonic DMC-GF5XEE-K Black Инструкция по эксплуатации
- Icom IC-T90A Инструкция по эксплуатации
- Panasonic DMC-GF5XEE-R Red Инструкция по эксплуатации
- Icom IC-T22A Инструкция по эксплуатации
- Panasonic DMC-GF5XEE-W White Инструкция по эксплуатации
- Icom IC-T81A Инструкция по эксплуатации
- Samsung ES90 Black Инструкция по эксплуатации
- Icom IC-V8 Инструкция по эксплуатации
- Samsung ES90 Red Инструкция по эксплуатации
- Icom IC-V85 Инструкция по эксплуатации
- Samsung ES90 Silver Инструкция по эксплуатации
- Icom IC-W32A Инструкция по эксплуатации
- Ardo 56 GG40 VX Инструкция по эксплуатации
- Samsung ST76 Red Инструкция по эксплуатации
- Icom ID-800H Инструкция по эксплуатации
- Ardo 56 GG40 X Инструкция по эксплуатации