Asus ESC4000 G4 [74/202] V 127vac 12 a 50 60hz 1000w 200v 240vac 9 a 50 60hz 1600w

Asus ESC4000 G4 [74/202] V 127vac 12 a 50 60hz 1000w 200v 240vac 9 a 50 60hz 1600w
Chapter 2: Hardware Setup
2-46
The system automatically combines the two power supply modules as a single one.
The combined output power varies with input voltages. Refer to the table below for
details.
Input Voltage Max. Output Power (Watt) per PSU
100V—127Vac, 12.9A, 50-60Hz 1000W
200V—240Vac, 9.5A, 50-60Hz 1600W
To enable the hot-swap feature (redundant mode), keep the total power consumption
of the system under the maximum output power of an individual power supply module.
Always use PSUs with the same watt and power rating. Combining PSUs with different
wattage (e.g. 1 x 1620 W + 1 x 2000 W) may yield unstable results and potential
damage to your system.
For a steady power input, use only the power cables that come with the server system
package.