Daikin CDX25AVMA [158/268] Wiring

Daikin CDK60AVMA [158/268] Wiring
ED12-321A Indoor Units
Installation Manual 153
4
125
60
83
503.5 44.5
290
52
1050
99.5
52 90 55
100
100
3) Shape the refrigerant pipe along the pipe path marking on the
mounting plate.
4) Pass drain hose and refrigerant pipes through the wall hole,
then set the indoor unit on mounting plate hooks, using the
markings at the top of indoor unit as a guide.
5) Pull in the interconnecting wires.
6) Connect the inter-unit piping.
7)
Wrap the refrigerant pipes and drain hose together with insulation
tape as right figure, in case of setting the drain hose through the back
of the indoor unit.
8) While exercising care so that the
interconnecting wires do not catch
indoor unit, press the bottom edge of
indoor unit with both hands until it is
firmly caught by the mounting plate
hooks. Secure indoor unit to the
mounting plate with screws (M4 × 12L).
3-3. Wall Embedded Piping
Follow the instructions given under
1) Insert the drain hose to this
depth so it wont be pulled out
of the drain pipe.
4. Wiring.
, install as described in the installation
manual supplied with the Multi outdoor unit.
1) Strip wire ends (15 mm).
2) Match wire colours with terminal
numbers on indoor and outdoor units
terminal blocks and firmly screw wires
to the corresponding terminals.
3) Connect the earth wires to the
corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then
retain wires with wire retainer.
5) In case of connecting to an adapter system. Run the remote control
cable and attach the S21 connector as the illustration above.
6) Shape the wires so that the service lid fits securely, then close
service lid.
Wrap insulating tape around the bent portion
of refrigerant pipe.
Overlap at least half the width of the tape
with each turn.
Drain
hose
Caulk this hole
with putty or
caulking material.
Bind with plastic
tape.
A
Mounting plate
Refrigerant
pipes
Drain hose
Bottom frame
H M4 × 12L (2 point)
Mounting
plate
A
Left-Side, Left-Back, or Left Bottom Piping
Inner wall
Vinyl chloride
drain pipe
(VP-30)
Drain hose50 mm
or more
Insert drain hose
to this depth so
it wont be pulled
out of drain pipe.
Outer wall
With a Multi indoor unit
Shape wires so that the service
lid will fit securely.
Terminal block
Electrical component box
Wire retainer
Firmly secure wire retainer
so that wires sustain no
external stress.
Use the specified wire type.
1
2
3
123 LN
Safety
breaker
20A
Earth leakage
circuit breaker
Earth
When wire length exceeds
10 m, use 2.0-mm wires.
H05VV
Firmly fix the wires with
the terminal screws.
Outdoor unit
Indoor
unit
Power
supply
50Hz 220V - 240V
60Hz 220V - 230V
Firmly fix the wires with
the terminal screws.
Do not use tapped wires, stand wires, extensioncords, or starbust connections,
as they may cause overtheating, electrical shock,or fire.
Warning