8 | Configuration
Installer reference guide
148
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
# Code Description
N/A [1-05] Weather dependent cooling of the additional
leaving water temperature zone is…
0 (disabled)
1 (enabled) (default)
Temperature ranges (room temperature)
ONLY applicable in room thermostat control. In order to save energy by preventing
overheating or undercooling the room, you can limit the range of the room
temperature, both for heating and/or cooling.
NOTICE
When adjusting the room temperature ranges, all desired room temperatures are
also adjusted to guarantee they are between the limits.
# Code Description
Room temp. range
[A.3.2.1.2] [3-06] Maximum temp (heating)
18°C~30°C (default: 30°C)
[A.3.2.1.1] [3-07] Minimum temp (heating)
12°C~18°C (default: 12°C)
[A.3.2.1.4] [3-08] Maximum temp (cooling)
25°C~35°C (default: 35°C)
[A.3.2.1.3] [3-09] Minimum temp (cooling)
15°C~25°C (default: 15°C)
Room temperature step
ONLY applicable in room thermostat control and when the temperature is
displayed in °C.
# Code Description
[A.3.2.4] N/A Room temp. step
1°C (default). The desired room temperature
on the user interface is settable per 1°C.
0.5°C. The desired room temperature on the
user interface is settable per 0.5°C. The actual
room temperature is displayed with an
accuracy of 0.1°C.
Room temperature hysteresis
ONLY applicable in case of room thermostat control. The hysteresis band around
the desired room temperature is settable. It is recommended NOT to change the
room temperature hysteresis as it is set for an optimal use of the system.
[
9-0C
]
a
b
c
d
a Room temperature
b Actual room temperature