Daikin EHYHBH05AFV32 — руководство по установке для гибридных тепловых насосов [109/252]

Превью страниц Страница 109 / 252
Daikin EVLQ08CAV3 [109/252] Installation
7 | Installation
Installer reference guide
109
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
7.13.6 Flue pipe position
See the local and national regulations.
Especially for UK:
Only use flue products approved by the boiler manufacturer, which can be bought
from the supplier of your boiler.
See "5.3Combining units and options"[429].
P
S
C
B
A
M
R
D
J
Q
G
A
Q
Q
N
P
T2 T2
T2
T1
H
T
I
K
L
F
F
N
E
Terminal position Minimum distance
(mm)
A Directly below an open able window or other
opening (e.g. air brick)
300
B Below gutters, soil pipes or drain pipes 75
C Below eaves 200
D Below balconies or car front roofs
E From vertical drain pipes and soil pipe 150
F From internal or external corners 300
G Above ground, roof or balcony level
H From a surface facing a terminal 600