8 | Configuration
Installer reference guide
125
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
# Code Description
[A.2.1.7] [C-07] Unit temperature control:
0 (LWT control): Unit operation is decided
based on the leaving water temperature
regardless the actual room temperature and/or
heating or cooling demand of the room.
1 (Ext RT control): Unit operation is
decided by the external thermostat or
equivalent (e.g. heat pump convector).
2 (RT control)(default): Unit operation is
decided based on the ambient temperature of
the user interface.
[A.2.1.B] N/A Only if there are 2user interfaces (1 installed in
the room, 1 installed at the indoor unit):
a
b
a: At unit
b: In room as room thermostat
User interface location:
At unit: this user interface is used to control
the unit. The other user interface is
automatically set to In room.
In room (default): this user interface acts as
room thermostat. The other user interface is
automatically set to At unit