Daikin EHYHBH05AFV32 [97/252] Installation

Daikin EHYHBX08AFV3 [97/252] Installation
7 | Installation
Installer reference guide
97
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
7.11.12 To connect the gas meter
INFORMATION
In case of a gas meter with transistor output, check the polarity. The positive polarity
MUST be connected to X5M/9; the negative polarity to X5M/10.
1 Connect the gas meter cable to the appropriate terminals as shown in the
illustration below.
X1M
9
10
X5M
S3S
2 Fix the cable with cable ties to the cable tie mountings.
7.11.13 To connect the domestic hot water pump
1 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
35
34
X2M
X1M
X5M
1~
M
M2P
2 Fix the cable with cable ties to the cable tie mountings.
7.11.14 To connect the alarm output
1 Connect the alarm output cable to the appropriate terminals as shown in the
illustration below.

Содержание

Похожие устройства

Скачать