BEST BETA 60 BHC62350XA [18/76] Maintenance

BEST THETA 90 BHC93750XA [18/76] Maintenance
30h filter ALARM: After 30 hours of operation, an alarm switches on to
signal the need for anti-grease filter cleaning.The filter alarm, when active,
is displayed for 30 sec each time the motor is deactivated:BL6 remains
ON.During this period, it is possible to reset the alarm by pressing the TC6
button for longer than a second.
120h filter ALARM: After 120 hours of operation, an alarm switches on to
signal the need for active carbon filter (optional) replacement.The filter
alarm, when active, is displayed for 30 sec each time the motor is
deactivated:BL6 lighting blinking.During this period, it is possible to reset the
alarm by pressing the TC6 button for longer than a second.
Buttons TC5 + TC6 (ASC sensitivity): ASC odour sensor sensitivity can be
varied on 4 different levels as needed by pressing buttons TC5 and TCS
simultaneously for more than 1 second.The motor must be OFF and
automatic function NOT active.When sensitivity setting function is
activated:all BL switch OFF (no display) then BL6 activates FIX.After 1
second, the BL2-BL5 LEDs will show the set sensitivity value, BL2 for lower
sensitivity up to BL5 which indicates higher sensitivity. You can set a
different value using corresponding keys TC2, TC3, TC4 or TC5. To save
the new sensitivity, press TC6 or wait until the function deactivates
automatically.
It can be varied on your keyboard (for cleaning) with a long press of the
buttons TC1 and TC6 simultaneously. When the cleaning mode is active,
the keys TC1 and TC6 remain lit. To exit cleaning is necessary to activate
the buttons again TC1 and TC6 pressed simultaneously (long), or wait for 5
minutes.
Work Time Limit: if the hood is left on (lights and/or motor), after 10 hours
in the absence of commands from the user, it will automatically switch to
OFF condition with all services switched off.
Buzzer: the Buzzer emits a "beep" each time that a command is set from
the keyboard or remote control (optional).
Controls of Fig. 49
Key A: light switch;- position 0: light off;- position 1: light on.
Key B: motor switch; - position 0: motor off; - position 1-2-3: motor first,
second and thrid speed motor on.
MAINTENANCE
! Before cleaning or maintenance cut the power.
Cleaning the hood
WHEN TO CLEAN IT: clean it at least every 2 months to prevent the risk
of fire.
EXTERNAL CLEANING: use a cloth moistened in lukewarm water and
neutral detergent (for painted hoods); use specific products for steel,
copper or brass hoods.
INTERNAL CLEANING: use a cloth (or brush) soaked in denatured ethyl
alcohol.
WHAT NOT TO DO: do not use abrasive or corrosive products (e.g. metal
sponges, brushes, too hard brushes, very aggressive detergents, etc.)
Cleaning the grease filters
WHEN TO CLEAN IT: clean it at least every 2 months to prevent the risk
of fire, in according to use.
HOW TO REMOVE THE FILTERS: push the catch near the handle towards
the rear of the hood and pull the filter downwards
HOW TO CLEAN THE FILTERS: hand wash or in the dishwasher using a
neutral detergent. If washing in the dishwasher, possible discoloration of the
filters does not in any way compromise their functioning.
Replacing the charcoal filter
(for filtering version only)
WHEN TO REPLACE IT: replace it at least every 6 months, in according to
use.
HOW TO REMOVE IT: If using the hood in the filtering version, the
charcoal filter will have to be replaced. To switch off, pull the latch inward
and rotate the filter downwards.
Lighting
Replace it with lamps of the same type; if a lamp is not listed in the table
shown in the “Warning” worksheet, please contact the support center.

Содержание

Похожие устройства

30h filter ALARM After 30 hours of operation an alarm switches on to signal the need for anti grease filter deaning The filter alarm when active is displayed for 30 sec each time the motor is deactivated BL6 remains ON During this period it is possible to reset the alarm by pressing the TC6 button for longer than a second 120h filter ALARM After 120 hours of operation an alarm switches on to signal the need for active carbon filter optional replacement The filter alarm when active is displayed for 30 sec each time the motor is deactivated BL6 lighting blinking During this period it is possible to reset the alarm by pressing the TC6 button for longer than a second Buttons TC5 TC6 ASC sensitivity ASC odour sensor sensitivity can be varied on 4 different levels as needed by pressing buttons TC5 and TCS simultaneously for more than 1 second The motor must be OFF and automatic function NOT active When sensitivity setting function is activated all BL switch OFF no display then BL6 activates FlX After 1 second the BL2 BL5 LEDs will show the set sensitivity value BL2 for lower sensitivity up to BL5 which indicates higher sensitivity You can set a different value using corresponding keys TC2 TC3 TC4 or TC5 To save the new sensitivity press TC6 or wait until the function deactivates automatically It can be varied on vour keyboard for cleaning with a long press of the buttons TC1 and TC6 simultaneously When the cleaning mode is active the keys TC1 and TC6 remain lit To exit cleaning is necessary to activate the buttons again TC1 and TC6 pressed simultaneously long or wait for 5 minutes Work Time Limit if the hood is left on lights and or motor after 10 hours in the absence of commands from the user it will automatically switch to OFF condition with all services switched off Buzzer the Buzzer emits a beep each time that a command is set from the keyboard or remote control optional Controls of Fig 49 Key A light switch position 0 light off position 1 light on Key B motor switch position 0 motor off position 1 2 3 motor first second and thrid speed motor on MAINTENANCE Before cleaning or maintenance cut the power Cleaning the hood WHEN TO CLEAN IT clean it at least every 2 months to prevent the risk of fire EXTERNAL CLEANING use a cloth moistened in lukewarm water and neutral detergent for painted hoods use specific products for steel copper or brass hoods INTERNAL CLEANING use a cloth or brush soaked in denatured ethyl alcohol WHAT NOT TO DO do not use abrasive or corrosive products e g metal sponges brushes too hard brushes very aggressive detergents etc Cleaning the grease filters WHEN TO CLEAN IT clean it at least every 2 months to prevent the risk of ire in according to use HOW TO REMOVE THE FILTERS push the catch near the handle towards the rear of the hood and pull the filter downwards HOW TO CLEAN THE FILTERS hand wash or in the dshwasher using a neutral detergent If washing in the dishwasher possible discoloration of the filters does not in any way compromise their functioning Replacing the charcoal filter for filtering version only WHEN TO REPLACE IT replace it at least every 6 months in according to use HOW TO REMOVE IT If using the hood in the filtering version the charcoal filter will have to be replaced To switch off pull the latch inward and rotate the filter downwards Lighting Replace it with lamps of the same type if a lamp is not listed in the table shown in the Warning worksheet please contact the support center