Comprag D-4508 [8/92] Technical data and functional description

Comprag D-4508 [8/92] Technical data and functional description
8
Version 1.4
16. Before beginning work in normal mode after maintenance or repair work, check that the
working pressure, temperature and other characteristics are correctly set. Ensure that all con-
trol devices are installed and functioning properly.
17. When replacing lters, separators etc., wipe away dust, dirt and oil residue from the area
where they are installed with a dry cloth.
18. Protect the motor, air lter, electrical components and control components etc. from com-
ing into contact with condensate. For instance, blow down with dry air.
19. Use protective gloves during installation and repair work in order to avoid burns and injury
(for instance, during oil change).
2.
Technical data and functional description
Entitlement to free handling of faults arising during the guarantee
period is forfeited when:
- No warranty service coupon for the compressor or it is
lled
out
incorrectly
- No
records
for the
compressor’s scheduled maintenance
are
entered in the
compressor’s
service book
- Unoriginal parts and
lubricants
are used
2.1 Technical data
Article Model
Drive
po
w
er
,
compressor
(kW)
Max.
operat-
ing
pressure
(bar)
Output*
(m³/min)
Rated
v
oltage
,
compressor
(phase/V/Hz)
Noise**
(dB)
Screw
connection
Oil
capac-
ity***,
liter
11300061 D3008
30
8 5,0
3/380-
420/50
70
1-1/4 15
11300062 D3010 10 4,5
11300071 D3708
37
8 6,2
72
11300072 D3710 10 5,6
11300081 D4508
45
8 7,0
73 1-1/2 20
11300082 D4510 10 6,2
11300091 D5508
55
8 9,1
11300092 D5510 10 8,5
* Gemessen nach ISO 1217; ** Gemessen nach ISO 3744

Содержание