Ariete Moka Aroma 1358 [12/53] Troubleshooting

Ariete Moka Aroma 1358 [12/53] Troubleshooting
12



Immediately turn the machine off if there are operational problems. Unplug it from the electric outlet. Wait for the
machine to cool down. As an alternative, use gloves or rags to unscrew the boiler from the carafe.
Problems Causes Solutions
The coffee does not
come out
There is no water in the boiler. Repeat the operation by putting the right amount of water
into the boiler.
Coffee comes out from
the edges of the boiler.
Probably too much ground coffee
was put in the funnel lter, and it
prevented the boiler from being
completely tightened to the
carafe.
Repeat the operation by putting the right amount of coffee
into the funnel lter.
Residue of ground coffee is on
the seal.
Clean the seal with a toothpick or a sponge.
The exit holes of the disc lter
(D) are clogged.
Turn off the machine. Unplug it from the socket-outlet.
Use gloves or rags. Wait for the machine to cool down.
Unscrew the boiler from the carafe. Remove the lter from
the carafe. Clean the clogged disc lter (Fig. 4) holes
using using a small brush or pin.
The seal is burnt or torn Replace the seal.
The carafe has not been tight-
ened to the boiler.
Screw the carafe onto the boiler tightly. Do not prize the
handle.
The coffee is not sup-
plied or ows too slowly.
The exit holes of the disc lter
(D) are clogged.
Turn off the machine. Unplug it from the socket-outlet.
Use gloves or rags. Wait for the machine to cool down.
Unscrew the boiler from the carafe. Remove the lter from
the carafe. Clean the clogged disc lter (Fig. 4) holes
using using a small brush or pin.
The coffee blend is ground too
ne.
Try using coarser coffee blends.
The coffee blend is pressed
down too much.
Put a smaller amount of coffee into the funnel lter.
Lime has formed on the bottom
of the boiler.
Descale as instructed in the paragraph “Cleaning the
appliance”.
The coffee is too watery
and cold.
The blend has been ground too
coarsely.
A more nely ground blend must be used to obtain a more
concentrated and hotter coffee.
Too much water has been put
inside.
Repeat the operation by putting the right amount of water
into the boiler. Up to the safety valve if the four cups of
coffee funnel lter is used. Beneath the safety valve if the
two cups of coffee adaptor disc is used (Fig. 2).

Содержание

Скачать