Kramer VP-440 [39/59] Default communication parameters

Kramer VP-440 [39/59] Default communication parameters
34
VP-440 - Technical Specifications
7.1 Default Communication Parameters
RS-232
Baud Rate:
9,600
Data Bits:
8
Stop Bits:
1
Parity:
None
Ethernet
To reset the IP settings to the factory reset values go to : Menu-> Factory-> RESET->Change
the option to YES and press Enter
IP Address:
192.168.1.39
Subnet mask:
255.255.0.0
Default gateway:
0.0.0.0
Default UDP Port #:
50000
Maximum UDP Ports:
4
Max. # of concurrently connected clients
1
Full Factory Reset
OSD
RS-232/Ethernet (UDP) Command Protocol
Command Format:
ASCII protocol 3000
Example (Route the video HDMI3 input to the output):
#ROUTE 12,1,2<cr>
7.2 Input Resolutions
Resolution/Refresh Rate
PC 1/PC 2
HDMI 1-10
640x480 (60/72/75/85Hz)
Yes
Yes
800x600 (56/60/72/75/85Hz)
Yes
Yes
1024x768 (60/70/75/85Hz)
Yes
Yes
1280x720 60Hz
Yes
Yes
1280x800 60Hz
Yes
Yes
1280x1024 (60/75/85Hz)
Yes
Yes
1366x768 60Hz
Yes
Yes
1400x1050 60Hz
Yes
Yes
1440x900 60Hz
Yes
Yes
1600x1200 60Hz
Yes
Yes
1600x900 RB 60Hz
Yes
Yes
1680x1050 RB 60Hz
Yes
Yes
1920x1080 60Hz
Yes
Yes
1920x1200 RB 60Hz
Yes
Yes
480I/576I
No
Yes
480P/576P
No
Yes
720P 50Hz
No
Yes
720P 60Hz
Yes
Yes
1080I(50/60Hz)
No
Yes
1080P(24/25/30Hz)
No
Yes
1080P 50Hz
No
Yes
1080P 60Hz
Yes
Yes

Содержание