Carefully remove the lid from the cartridge.
Slide the cartridge from the rear side into the base
of the station until it snaps into place.
Slowly close the housing by pushing it down until it
locks.
Using the special cord set (10), connect the
station power socket (13) to an electrical outlet.
Charging the shaver in the Clean&Charge station
Insert the shaver head down into the Clean&Charge
station.
Important: The shaver needs to be dry and free
from any foam or soap residue!
The contacts (7) on the back of the shaver need to
align with the contacts (15) in the Clean&Charge
station. Push the shaver in the correct position.
A beep sound confirms that the shaver sits properly
in the station. The Clean&Charge station will
automatically charge the shaver.
Cleaning the shaver
When the cleaning indicator lights up in the shaver
display, insert the shaver into the Clean&Charge
station, upside down and with the front showing.
Start automatic cleaning
Start the cleaning process by pressing the start
button (17). If the status light (16b) does not shine
(Clean&Charge station switches to stand-by after
about 10 minutes), press the start button twice.
Otherwise cleaning will not start.
For best shaving results, we recommend
cleaning after each shave.
The cleaning program consists of several cycles,
where cleaning fluid is flushed through the shaver
head. The cleaning time takes 3 minutes. During this
time the status light of the Clean&Charge station
blinks.
Leave the shaver in the station for drying. It takes
several hours until remaining moisture evaporates
depending on the climatic conditions. Afterwards
the shaver is ready for use.
After completing the cleaning and charging session,
the indicators of the Clean&Charge station turn off.
Removing the shaver from the Clean&Charge
station (see fig. F)
Hold the Clean&Charge station with one hand and
tilt the shaver slightly to the front to release it.
Cleaning Cartridge / Replacement (see fig. G)
When the level indicator
lights up permanently
red, the remaining fluid in the cartridge is sufficient
for about 3 more cycles. When the level indicator
blinks red, the cartridge needs to be replaced
(about every 3–4 weeks when used daily).
After having pressed the lift button (14) to open the
housing, wait for a few seconds before removing
the used cartridge to avoid any dripping. Before
discarding the used cartridge, make sure to close
the openings using the lid of the new cartridge,
since the used cartridge will contain contaminated
cleaning solution.
The hygienic cleaning cartridge contains ethanol or
izopropanol (dependent on country – specification
see cartridge), which once opened will naturally
evaporate slowly into the surrounding air.
Each cartridge, if not used daily, should be replaced
after approximately 8 weeks to ensure optimal
disinfection.
The cleaning cartridge also contains lubricants, for
the shaving system which may leave residual marks
on the outer foil frame and the cleaning chamber
of the Clean&Charge station after cleaning. These
marks can be removed easily by wiping gently with a
damp cloth.
Accessories
Braun recommends changing your shaver’s
Foil & Cutter cassette every 18 months to maintain
your shaver’s maximum performance.
Available at your dealer or Braun Service Centres:
Foil & Cutter cassette: 40S/40B
Cleaning cartridge Clean&Charge: CCR
Environmental notice
This product contains rechargeable batteries.
In the interest of protecting the environment,
please do not dispose of the product in the
household waste at the end of its useful life.
Disposal can take place at a Braun Service Centre
or at appropriate collection points provided in your
country.
The cleaning cartridge can be disposed of with
regular household waste.
Subject to change without notice.
For electrical specifications, see printing on the
special cord set.
92388018_CoolTec_CEEMEA_S6-76.indd 892388018_CoolTec_CEEMEA_S6-76.indd 8 22.10.12 13:5722.10.12 13:57

Содержание

Carefully remove the lid from the cartridge Slide the cartridge from the rear side into the base of the station until it snaps into place Slowly close the housing by pushing it down until it locks Using the special cord set 10 connect the station power socket 13 to an electrical outlet Charging the shaver in the Clean Charge station Insert the shaver head down into the Clean Charge station Important The shaver needs to be dry and free from any foam or soap residue The contacts 7 on the back of the shaver need to align with the contacts 15 in the Clean Charge station Push the shaver in the correct position A beep sound confirms that the shaver sits properly in the station The Clean Charge station will automatically charge the shaver After having pressed the lift button 14 to open the housing wait for a few seconds before removing the used cartridge to avoid any dripping Before discarding the used cartridge make sure to close the openings using the lid of the new cartridge since the used cartridge will contain contaminated cleaning solution The hygienic cleaning cartridge contains ethanol or izopropanol dependent on country specification see cartridge which once opened will naturally evaporate slowly into the surrounding air Each cartridge if not used daily should be replaced after approximately 8 weeks to ensure optimal disinfection The cleaning cartridge also contains lubricants for the shaving system which may leave residual marks on the outer foil frame and the cleaning chamber of the Clean Charge station after cleaning These marks can be removed easily by wiping gently with a damp cloth Cleaning the shaver When the cleaning indicator A lights up in the shaver display insert the shaver into the Clean Charge station upside down and with the front showing Start automatic cleaning Accessories Braun recommends changing your shaver s Foil Cutter cassette every 18 months to maintain your shaver s maximum performance Start the cleaning process by pressing the start button 17 If the status light 16b doesnot shine Clean Charge station switches to stand by after about 10 minutes press the start button twice Otherwise cleaning will not start For best shaving results we recommend cleaning after each shave The cleaning program consists of several cycles where cleaning fluid is flushed through the shaver head The cleaning time takes 3 minutes During this time the status light of the Clean Charge station blinks Leave the shaver in the station for drying It takes several hours until remaining moisture evaporates depending on the climatic conditions Afterwards the shaver is ready for use After completing the cleaning and charging session the indicators of the Clean Charge station turn off Available at your dealer or Braun Service Centres Foil Cutter cassette 40S 40B Cleaning cartridge Clean Charge CCR Removing the shaver from the Clean Charge station see fig F Subject to change without notice Hold the Clean Charge station with one hand and tilt the shaver slightly to the front to release it For electrical specifications see printing on the special cord set Cleaning Cartridge Replacement see fig G When the level indicator 1 1 lights up permanently red the remaining fluid in the cartridge is sufficient for about 3 more cycles When the level indicator blinks red the cartridge needs to be replaced about every 3 4 weeks when used daily 8 Environmental notice This product contains rechargeable batteries In the interest of protecting the environment please do not dispose of the product in the household waste at the end of its useful life Disposal can take place at a Braun Service Centre or at appropriate collection points provided in your country The cleaning cartridge can be disposed of with regular household waste