Daikin FXDQ25PVET Сервис мануал онлайн [393/394] 544102

Daikin FXDQ20PVET Сервис мануал онлайн [393/394] 544101
Si34-704
vi Drawings & Flow Charts
Malfunction of Thermistor (R2T),
(R7T) for Suction Pipe
..................................238
Malfunction of Thermistor (R3T) for
Gas Pipes
.....................................................212
Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger
.......................239
Malfunction of Thermostat Sensor in
Remote Controller
.........................................215
Malfunction of Transmission between
Centralized Controller and Indoor Unit
..........287
Malfunction of Transmission between Indoor and
Outdoor Units in the Same System
...............282
Malfunction of Transmission between
Indoor Units
...................................................271
Malfunction of Transmission between Inverter and
Control PC Board
..........................................257
Malfunction of Transmission between Main and
Sub Remote Controllers
................................281
Malfunction of Transmission between Optional
Controllers for Centralized Control
................294
Malfunction of Transmission between
Outdoor Units
................................................275
Malfunction of Transmission between
Remote Controller and Indoor Unit
...............274
Method of Checking the Inverter’s Power Transistors
and Diode Modules
.......................................364
Momentary Overcurrent of
Inverter Compressor
............................ 250
,
252
O
Operation Lamp Blinks
.........................................298
Operation of the Remote Controller’s Inspection /
Test Operation Button
...................................187
Outdoor Unit PC Board Layout
............................144
P
PC Board Defect
................................. 199
,
216
,
293
Piping Diagrams
...................................................314
Indoor Unit
.....................................................318
Outdoor Unit
..................................................314
Piping Installation Point
........................................356
The Example of a Wrong Pattern
..................357
Power Supply Insufficient or
Instantaneous Failure
...................................267
Pressure Sensor
..................................................363
R
Refrigerant Flow for Each Operation Mode
............74
Refrigerant Overcharged
.....................................231
Remote Controller Self-Diagnosis Function
.........190
Remote Controller Service Mode
.........................188
Reverse Phase, Open Phase
..............................266
RXQ10P
.................................................................71
RXQ14P, 16P, 18P
................................................73
RXQ5P
...................................................................69
RXQ8P
...................................................................70
S
Self-diagnosis by Wired Remote Controller
........ 183
Self-diagnosis by Wireless Remote Controller
.... 184
Setting of Low Noise Operation and
Demand Operation
....................................... 169
Image of operation in the case of A
...... 170
,
172
Image of operation in the case of A
and B
....................................... 170
,
172
Image of operation in the case of B
...... 170
,
172
Simplified Remote Controller
.............................. 147
BRC2A51, BRC2C51
.................................... 147
System is not Set yet
.......................................... 290
T
Test Operation
.................................................... 128
Thermostat Sensor in Remote Controller
............ 119
Cooling
.......................................................... 119
Torque wrench
.................................................... 373
Transmission Failure (Across Outdoor Units)
..... 275
Troubleshooting
(OP: Central Remote Controller)
.................. 293
Troubleshooting
(OP: Unified ON/OFF Controller)
................. 298
Troubleshooting by Remote Controller
............... 182
W
Weigher for refrigerant charge
............................ 376
Wired Remote Controller
..................................... 145
Wireless Remote Controller - Indoor Unit
........... 146
BRC4C type
.................................................. 146
BRC7C type
.................................................. 146
BRC7E type
.................................................. 146
Wiring Diagrams for Reference
........................... 321
Field Wiring
................................................... 326
Indoor Unit
.................................................... 329
Outdoor Unit
................................................. 321

Содержание