Daikin FTKE35BVMA [105/268] Super multi nx b series heat pump

Daikin FTKE25BVMT [105/268] Super multi nx b series heat pump
Capacity Tables ED12-321A
100 SUPER MULTI NX B-Series Heat Pump
3D042742#7
3D042742#8
Combination
(Capacity)
Indoor
Air Temp.
°CDB
Outdoor Air Temp.:°CWB
-15 -10 -5 0 6 10 15
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
2.5+2.5+6.0 16 5.57 2.09 6.53 2.24 7.58 2.40 8.50 2.52 9.69 2.67 10.52 2.78 11.59 2.93
18 5.55 2.15 6.51 2.31 7.55 2.46 8.47 2.58 9.64 2.74 10.47 2.86 11.53 3.01
20 5.53 2.22 6.49 2.38 7.53 2.53 8.44 2.65
9.60 2.82 10.42 2.94 11.48 3.10
21 5.52 2.25 6.48 2.41 7.52 2.56 8.42 2.69 9.58 2.86 10.39 2.98 11.45 3.14
22 5.50 2.29 6.47 2.44 7.51 2.60 8.41 2.73 9.56 2.90 10.37 3.02 11.42 3.19
24 5.48 2.36 6.45 2.51 7.49 2.67 8.38 2.81 9.52 2.99 10.32 3.11 11.37 3.29
2.5+3.5+3.5 16 5.48 2.35 6.43 2.52 7.46 2.70 8.37 2.83 9.54 3.00 10.35 3.13 11.41 3.30
18 5.46 2.42 6.41 2.59 7.44 2.77 8.34 2.91 9.49 3.08 10.30 3.21 11.35 3.39
20 5.44 2.50 6.39 2.67 7.41 2.84 8.30 2.98
9.45 3.17 10.25 3.30 11.30 3.48
21 5.43 2.53 6.38 2.71 7.40 2.88 8.29 3.03 9.43 3.21 10.23 3.35 11.27 3.53
22 5.42 2.57 6.37 2.75 7.39 2.92 8.27 3.07 9.41 3.26 10.21 3.40 11.25 3.59
24 5.48 2.65 6.45 2.82 7.49 3.00 8.38 3.16 9.52 3.36 10.32 3.50 11.37 3.69
2.5+3.5+5.0 16 5.57 2.12 6.53 2.27 7.58 2.44 8.50 2.56 9.69 2.71 10.52 2.82 11.59 2.97
18 5.55 2.18 6.51 2.34 7.55 2.50 8.47 2.62 9.64 2.78 10.47 2.90 11.53 3.06
20 5.53 2.25 6.49 2.41 7.53 2.56 8.44 2.69
9.60 2.86 10.42 2.98 11.48 3.14
21 5.52 2.29 6.48 2.44 7.52 2.60 8.42 2.73 9.58 2.90 10.39 3.02 11.45 3.19
22 5.50 2.32 6.47 2.48 7.51 2.63 8.41 2.77 9.56 2.94 10.37 3.07 11.42 3.23
24 5.48 2.39 6.45 2.54 7.49 2.71 8.38 2.85 9.52 3.03 10.32 3.16 11.37 3.33
3.5+3.5+3.5 16 5.54 2.27 6.50 2.44 7.54 2.62 8.46 2.74 9.64 2.91 10.46 3.03 11.53 3.19
18 5.52 2.34 6.48 2.51 7.51 2.68 8.42 2.81 9.59 2.99 10.41 3.11 11.47 3.28
20 5.50 2.42 6.46 2.59 7.49 2.75 8.39 2.89
9.55 3.07 10.36 3.20 11.42 3.37
21 5.49 2.45 6.45 2.62 7.48 2.79 8.38 2.93 9.53 3.11 10.34 3.25 11.39 3.42
22 5.48 2.49 6.43 2.66 7.47 2.83 8.36 2.97 9.51 3.16 10.32 3.29 11.37 3.47
24 5.45 2.56 6.41 2.73 7.45 2.91 8.33 3.06 9.47 3.25 10.27 3.39 11.31 3.58
Symbols NOTE:
TC : Total capacity (kW) Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5m
Level difference : 0m
PI : Power input (kW)