Daikin FTKE35BVMA [162/268] Accessories

Daikin 4MXD80BVMA [162/268] Accessories
ED12-321A Indoor Units
Installation Manual 157
4
2.3 Duct Connected Type CDK(X) 25/35/50/60 A
ACCESSORIES
CHOOSING A SITE
Before choosing the installation site, obtain user approval.
Indoor unit
Optimum air distribution is ensured.
The air passage is not blocked.
Condensate can drain properly.
The ceiling is strong enough to bear the weight of the indoor unit.
A false ceiling does not seem to be at an incline.
Sufficient clearance for maintenance and servicing is ensured.
Piping between the indoor and outdoor units is within the allowable limits.
(Refer to the installation manual for the outdoor unit.)
The indoor unit, outdoor unit, power supply wiring and transmission wiring
is at least 1 meter away from televisions and radios. This prevents image
interference and noise in electrical appliances. (Noise may be generated
depending on the conditions under which the electric wave is generated,
even if a one-meter allowance is maintained.)
Use suspension bolts to install the unit. Check whether or not the ceiling
is strong enough to support the weight of the unit. If there is a risk that
the ceiling is not strong enough, reinforce the ceiling before installing
the unit.
Select the signal receiver mounting location within the signal receiver
mounting area according to the following conditions:
Since the receiver has a built-in temperature sensor, do not mount it in an
area where it will be subject to direct sunlight or to cold or hot air coming
from the air discharge grill of the air conditioner.
Since the receiver has a built-in light receptor to receive signals from the
wireless remote control, do not mount it in a location where the signal
may be blocked by a curtain, etc.
Wireless Remote Controller
Turn on all the fluorescent lamps in the room, if any, and find the site where remote
control signals are properly received by the indoor unit (within 4 metres).
Outdoor unit
For outdoor unit installation, see the installation manual supplied with the Multi outdoor unit.
Clamp metal
1
Insulation for fitting
1 each
for gas pipe
for liquid pipe
Large
Small
Sealing pad
Large and small
1 each
Wireless remote controller
1
Remote control holder
AAA dry-cell batteries
Faceplate;
faceplate frame
Insulated
mounting frame
Screws
M4 × 25
Decorative
cover
1 1 set
Reciever kit
2 1 1 2
[ Other ]
Operation
manual
Installation
manual
Units: mm
270 or more
300 or more
(Service space)
Power supply
wiring port
Drain pipe
Gas pipe
Liquid pipe
20 mm Min.Air discharge grill
Signal receiver mounting area

Содержание

Скачать