Daikin RKS60E2V1B [124/258] Troubleshooting

Daikin RKS60E2V1B [124/258] Troubleshooting
SiBE04-609 Troubleshooting
Service Diagnosis 115
4. Troubleshooting
4.1 Error Codes and Description
+
: Displayed only when system-down occurs.
Code Indication Description
Reference
Page
System
00
Normal
U0+
Insufficient gas
143
U2
Low-voltage detection or over-voltage detection
145
U4
Signal transmission error (between indoor and outdoor units)
122
Indoor
Unit
A1
Indoor unit PCB abnormality
116
A5
Freeze-up protection control or high pressure control
117
A6
Fan motor or related abnormality
119
C4
Heat exchanger thermistor abnormality
121
C9
Room temperature thermistor abnormality
121
Outdoor
Unit
E1
Outdoor unit PCB abnormality
123
E5+
OL activation (compressor overload)
124
E6+
Compressor lock
125
E7
DC fan lock
126
E8
Input over current detection
127
F3
Discharge pipe temperature control
129
H0
Sensor abnormality
130
H6
Position sensor abnormality
132
H8
CT or related abnormality
133
H9
Outdoor air thermistor or related abnormality
135
J3
Discharge pipe thermistor or related abnormality
135
J6
Heat exchanger thermistor or related abnormality
135
L3
Electrical box temperature rise
137
L4
Radiation fin temperature rise
139
L5
Output over current detection
141
P4
Radiation fin thermistor or related abnormality
135
U7
Signal transmission error
146

Содержание