Daikin FTXD50JV1B [32/164] Flap control

Daikin FTXD50JV1B [32/164] Flap control
General Functions SiBE04-101
24 Main Function
1.6 Flap Control
1.6.1 Wall Mounted J Type
Wide-angle Flap The large flaps send a large volume of air downwards to the floor. The flap provides an optimum control
area in cooling, heating and dry mode.
Diffuser In heating operation, it supports the function of the large flap and diffuses more warm air down to the floor.
Heating Mode During heating mode, the large flap enables direct warm air straight downwards. The diffuser presses the
warm air above the floor to reach the entire room.
Cooling Mode During cooling mode, the diffuser retracts into the indoor unit. Then, cool air can be blown far and pervaded
all over the room.
Louvres The louvres, made of elastic synthetic resin, provide a wide range of airflow that guarantees a comfortable
air distribution.
Auto Swing The following table explains the auto swing process for heating, cooling, dry and fan :
Item Description Drawing
Vertical
direction
Heating
The flap swings up and down as shown in
the drawing alongside.
Cooling,
Dry, Fan
The flap swings up and down as shown in
the drawing alongside.
Horizontal
direction
Heating,
Cooling
The flap swings right and left as shown in
the drawing alongside.
30˚
60˚
(R1017)
15˚
35˚
FLAP
(R1018)
60˚
60˚
(R1019)
SiBE04-101.book Page 24 Monday, October 15, 2001 3:08 PM