Daikin FTXD50JV1B [61/164] Preparation before operation

Daikin FTXD50JV1B [61/164] Preparation before operation
SiBE04-101 Instruction
System Configuration 53
9
Preparation Before Operation
Setting the air purifying filters
Indoor unit
Holding down ( ) or ( ) button
rapidly increases or decreases the time display.
NOTE
Setting the clock
Press .
Press
to set the clock to the
present time.
Turn the breaker ON
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
Pull out the air filters.
Push upwards the
tab at the center of
each air filter, then
pull it down.
2
Open the front grille.
Hold the grille by the tabs on the two sides
and lift it until it stops with a click.
(about 60˚)
1
û
C
Set the air purifying filters.
Attach an air purifying filter to each air filter.
(See page 16 “Care and cleaning”)
Set the air filters in their original
positions and close the front grille.
Operation without air filters may result in
troubles as dust will accumulate inside the
indoor unit.
3
4
1
is displayed.
2
blinks.
3
Please note
The air conditioner always consumes 15 – 35 watts of
electricity even while it is not operating.
If you are not going to use the air conditioner for a long period,
for example in spring or autumn, turn the breaker OFF.
Use the air conditioner in the following conditions.
Press .
blinks.
(Now the clock is set.)
Mode
COOL/
DRY
HEAT
Operating conditions
Outdoor temperature
RXD : –10 to 46 ˚C
2~3MX : 21 to 43 ˚C
4MX : 10 to 43 ˚C
Indoor temperature : 15 to 28 ˚C
Indoor humidity : 80% max. (*1)
Outdoor temperature
RXD : –15 to 24 ˚C
2~4MX : –10 to 24 ˚C
Indoor temperature : 10 to 30 ˚C
If operation is continued out of this range
A safety device may work to stop the
operation.
(In multi system, it may work to stop
the operation of the outdoor unit only.)
Condensation may occur on the
indoor unit and drip.
A safety device may work to stop the
operation.
(*1) Use in humidity 60% or lower when using the unit
at an outdoor temperature of 10˚C or lower.
Tips for saving energy
Be careful not to cool the room too much.
Keeping the temperature setting at a
moderate level helps save energy.
Recommended temperature setting
For cooling: 26˚C – 28˚C
For heating: 20˚C – 24˚C
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors
increases the cooling effect.
Clogged air filters cause inefficient
operation and waste energy. Clean them
once in about every two w
eeks.
SiBE04-101.book Page 53 Monday, October 15, 2001 3:08 PM