Daikin EKHWMX500CA [64/68] X technical data

Daikin EKHWMX300CA [64/68] X technical data
10 x Technical data
Installation and maintenance instructions
64
Daikin Altherma M ECH
2
O
Solar storage tank with heating controller
008.1446799_00 – 07/2019 – EN
10.3 Characteristic lines
10.3.1 Sensor characteristic lines
Temperature sensor
Measured temperature in °C
-20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
Sensor resistance in kOhm according to standard or manufacturer's indications
t
DHW
, t
V, BH
NTC
98.66 56.25 33.21 20.24 12.71 8.20 5.42 3.66 2.53 1.78 1.28 0.93 0.69 0.52 0.36
Tab. 10-4 Daikin Altherma M ECH
2
O sensor table
t
DHW
Storage tank temperature sensor
t
V, BH
Backup heater feed temperature sensor
Maximum sensor tightening torque =10 Nm.
R
S
Sensor resistance (NTC)
t Temperature
Fig. 10-2 Characteristic of the storage tank temperature sensor t
DHW
and the flow temperature sensor t
V, BH
Daikin Altherma M
ECH
2
O
p Water pressure
U Voltage
Fig. 10-3 Characteristic of pressure sensor (P
hyd
) Daikin Altherma M
ECH
2
O
10.4 Tightening torque
Component Thread
size
Tightening
torque
Temperature sensor all Max. 10 Nm
Hydraulic line connections (Water) 1" 25 to 30 Nm
Backup heater 1.5" max. 10 Nm
(hand-tight)
Tab. 10-5 Tightening torque