ENGLISH
35
To execute this operation, use the threaded insert set up in the hood structure and identified with a label and symbol .
It is recommended that you comply with the current regulations on electrical safety of systems and devices regarding earthing equipment.
Connection of the suction pipe between the hood and the under-roof (URS) or outdoor (URE) remote motor unit can be carried out
by means of the ange
(FC)
or air conveyor kit for rectangular pipes (CT) optional.
Follow the instructions according to the desired installation.
Connection between the hood and the remote unit by means of the air conveyor kit for rectangular pipes (CT) (OPTIONAL)
The conveyor kit for rectangular pipes (CT) enables connection of the hood to an under-roof
(URS) or outdoor (URE) remote motor
unit by means of suitable rectangular-section pipes.
The conveyor kit for rectangular pipes (CT) is optional.
Phase
O page 16
Remove the flange (FC) assembled on the hood (Fig.
1
).
Check the correct position between the elements (L) and (M), which form part of the support brackets of the conveyor kit (CT) for rectangular pipes
(Fig.
2
). If required, position them at the height indicated in (Fig.
3
) and secure them with 8 screws (V1).
Secure the support brackets (L+M) to the conveyor kit for rectangular pipes (CT) using the 4 screws (V2), taking the desired air outlet direction into
consideration (Fig.
4
).
Phase
P page 16
Place the assembly composed of the conveyor kit (CT) and its supports (L+M) on the false ceiling (Fig.
1
), taking care to centre the assembly by
means of the flaps (H) of the protection template (G) (Fig.
2
).
Phase
Q1 page 17
Connect the kit conveyor air outlet fitting for rectangular pipes (TC) to the under-roof (URS) or outdoor (URE) remote unit with a suitable (FR) pipe
(Fig.
1
)
.
Lift the hood towards the false ceiling (Fig.
2
) and pass the chains through the safety holes of the hood (Fig.
3
).
Lift the knockouts and insert the connector (CUE) from the under-roof (URS) or outdoor (URE) remote unit into the drilled hole (Fig.
4
).
Insert the hood in the previously reinforced false ceiling: as the hooks (G) open, they provisionally support the hood on the false ceiling (Fig.
5
).
Tighten
all screws (V3) in order to open the hooks (G) and lock the hood on the false ceiling (Fig.
6
).
Phase
Q2 page 17
Open the perimeter suction panel (Fig.
T
on page
20
), remove the metal filters (FM) (Fig. U on page
20
) and remove the piston (Fig. V on page
20
) (Fig.
1
).
Fasten the kit conveyor (CT) to the hood by means of 8 screws (V5) (Fig.
2
).
Connect
the (CUE)
connector of the under-roof (URS) or outdoor (URE)
remote unit to the hood connector (CE)
(Fig.
3
).
Fix the safety chains to the hood using the supplied screws (V4) and cut the excess chain (Fig.
4
).
To assemble the
under-roof
(URS) or outdoor (URE) remote motor unit, refer to the relative instructions booklet.
Hood and remote unit connection by means of the ange (FC)
The flange (FC), by means of suitable piping, connects the hood to the under-roof
(URS) or outdoor (URE) remote motor unit.
Phase R page 18
Should you wish to use a check valve, assemble it on the flange (FC) (Fig.
1
); lock it to the flange by pushing the flaps of the fitting downwards
with a screwdriver or grippers (Fig.
2
). If the under-roof (URS) remote motor unit is used, remove the check valve assembled on it (refer to the
instructions
F on page 11).
Phase
S1 page 18
Lift the hood towards the false ceiling (Fig.
1
) and connect the flange (FC) to the under-roof (URS) or outdoor (URE) remote unit with a suitable (F)
pipe (Fig.
2
)
.
Pass the chains through the safety holes of the hood (Fig.
3
).
Lift the knockouts and insert the connector (CUE) from the under-roof (URS) or outdoor (URE) remote unit into the drilled hole (Fig.
4
).
Insert the hood in the previously reinforced false ceiling: as the hooks (G) open, they provisionally support the hood on the false ceiling (Fig.
5
).
Tighten
all screws (V3) in order to open the hooks (G) and lock the hood on the false ceiling (Fig.
6
).
Phase
S2 page 19
Open the perimeter suction panel (Fig.
T
on page
20
), remove the metal filters (FM) (Fig. U on page
20
) and remove the piston (Fig. V on page
20
) (Fig.
1
).
Connect
the (CUE)
connector of the under-roof (URS) or outdoor (URE)
remote unit to the hood connector (CE)
(Fig.
2
).
Fix the safety chains to the hood using the supplied screws (V4) and cut the excess chain (Fig.
3
).
To assemble the
under-roof
(URS) or outdoor (URE) remote motor unit, refer to the relative instructions booklet.