Moxa MPC-2150Z-T [58/65] Etc elapsed time counter query

Moxa MPC-2150X-T [58/65] Etc elapsed time counter query
MPC-2150 Hardware Display Control Interface Commands
B-4
ETC (Elapsed Time Counter Query)
This command is to query the elapsed time that the MPC-2150 has been operated. The MPC-2150 will reply to
this command with an ACK attention code. The largest byte will be transmitted first.
The maximum indicator for this function is 99999 hours (defined into 5 bytes, numbers 0 to 9 each), equivalent
to 11 years. If this number is reached, the ETC will stop counting, and the ETC command will always reply with
maximum number of hours (99999).
Example:
Send ETC to query elapsed time:
0x07 0xFF 0x45 0x54 0x43 0x00 0x1D
ACK 99999 hours
06 FF 45 54 43 05 19 39 39 39 39 39 E2
GMB (Glass Display Control - Minimum Brightness)
This command is to set the minimum value limit for the brightness of touch keypad LED to make sure that the
LED indicators are still visible if they was previously adjusted down to a very low value. The range starts from
0x00 to 0x31 (0% - 100%). LEN=one date byte.
Example:
Command to set 30% Brightness.
0x07 0xFF 0x47 0x4D 0x42 0x01 0x22 0x10 0xEF
POT (Potentiometer Control)
The BR+/BR- key default value is Enable. Users can send this command to disable/enable BR+/BR- key. If the
data and data checksum of sending are incorrect, the data field of replying is current control status. LEN=one
date byte.
0x00 Brightness +/Brightness - Key Disable
0xFF Brightness +/Brightness - Key Enable
Example:
Disable the BR+/BR- Key.
0x07 0xFF 0x50 0x4F 0x54 0x01 0x05 0x00 0xFF
ACK
0x06 0xFF 0x50 0x4F 0x54 0x01 0x06 0x00 0xFF
SWI (Scalar Firmware Version Query)
This command is to query the scalar firmware version.
Example:
Query Scalar Firmware Version
0x07 0xFF 0x53 0x57 0x49 0x00 0x06