Pulsar Digisight N970 [7/66] Zeroing

Pulsar Digisight N970 [7/66] Zeroing
Install the batteries according to the instructions in Section “Installation of
batteries” or connect an external power supply.
Open the lens cap (13).
Turn on the riflescope turning the selector switch (2) to the “ON” position –
within a couple of seconds the display will light up.
Achieve a sharp image of onscreen symbols rotating the eyepiece
adjustment ring (1). After this adjustment no further dioptre adjustment should
be required, regardless of distance or other factors.
To adjust display brightness, rotate the controller (9). Brightness level from
0 to 20 is shown next to the icon in the upper part of the display.
Press the controller (9) to switch to display contrast setup mode. Rotate the
controller to change contrast level from 0 to 20, shown next to the icon i n
the upper part of the display.
You can select reticle color from one of the four options in the menu.
Choose a still object that is, for instance, 100 metres away.
Rotate the lens focus knob (11) to achieve best possible image sharpness. To
quickly adjust for a target 100m away, set the lens focus knob opposite mark
“100” on the lens focus knob.
Starting the scope and image setup
Warning! Focusing range may vary depending on the illumination level in the
daytime; mark “100 m” on the lens focus knob equates to around 10 metres.
To activate continuous digital zoom, press briefly the controller button three
times. Rotate the controller to set 4x digital zoom within the range from 3.5x to
14x (with 0.1x increment)
In low light conditions or in complete darkness turn on the built-in IR
Illuminator (5). The IR Illuminator has three power degrees select the
required one by turning the selector switch (2) to one of the three positions.
The status bar shows corresponding icon - or .
When finished, turn off the riflescope by turning the selector switch (2) to the
“OFF” position.
Close the lens cap (13).
ZEROING
11
The riflescope features two zeroing methods -“one shot zeroing” and using
FREEZE function. Zeroing should be done at operating temperatures, by
following the order of these steps:
One shot zeroing:
Select option «Zeroing» in menu M2, press
the controller.
Rotate the controller to select option “---“ (new
distance) (see Pic.3).
Set a distance, at which you would like to zero
the riflescope (for example 200m): rotate the
controller to select value from 0 to 9; a cursor is
located above the active parameter. To move
the cursor to the next digit, press the controller.
Press and hold the controller to go to the
zeroing display.
The following appears on the display: a red
auxiliary cross , horizontal arrows and
coordinates of the auxiliary cross
(Pic.4).
Please keep the reticle permanently on the
target's centre when moving the auxiliary cross.
Exit the menu «Zeroing» with a long press of
the controller button. Message OK confirms
successful operation. The reticle will now move
to the point of impact.
Note: the auxiliary cross moves only within the limiting frame (see pic.) that
defines its travel range: 80 clicks horizontally (+40/-40) and 100 clicks
vertically (+50/-50).
If you notice that the point of impact is beyond the limiting frame, make sure
that:
The mount on your weapon is correctly installed.
The optical axis of the riflescope is not too high relative to the optical axis of
the rifle's barrel.
The mounting rail on your weapon does not have a longitudinal inclination.
Attention! Do not turn off the riflescope before zeroing settings are
saved, otherwise your settings will be lost.
Take another shot - the point of impact should now match the aiming point.
Note: zeroing parameters (coordinates X; Y) are saved in the riflescope's
memory as Profile “A” (menu option “Weapon choice”, menu M1). If you
wish to zero in the riflescope using another weapon or another distance,
select first Profile “B” or “C” (further details are in the “Weapon choice”
section).
Mount the rifle with the riflescope installed on a bench rest.
Set a target at a distance of about 100m.
Adjust the riescope according to the instructions of Section 10
“OPERATION”.
Aim the firearm at the target centre and take a shot.
If the point of impact did not match the aiming point, press and hold the
controller button (9) to enter menu.
Rotate the controller to move the auxiliary cross horizontally or vertically
relative to the reticle until the auxiliary cross matches the point of impact
(Pic. 5).
To switch between movement directions, push shortly the controller button.
Vertical lines appear next to the icon .
Pic.5
24
42
A333
A300 3.3x
Using the “FREEZE” function:
Do the points 1-9 of the section “One shot zeroing”.
After the auxiliary cross appears and arrows press button (10) on the upper
panel (or RC button (18) to freeze the image. Icon appears in the left
bottom part of the display.
Do the points 8-10 of the section “One shot zeroing”.
Note: after the image is “frozen”, there is no need to aim at the target.
After exiting the menu, the image returns to normal.