Tp-Link T1700G-28TQ V2 [295/354] Syntax
f-event
—— Fall Event, which is the index of the corresponding event which
will be triggered if the sampled value is lower than the
Falling Threshold. It
ranges from 1 to 12.
a-type —— Alarm Type, with rise, fall and all options. Rise indicates that the
alarm event will be triggered when the sampled value exceeds the
Rising
Threshold
, fall indicates that the alarm event will be triggered when the
sampled value is under the
Falling Threshold, and all indicates that the alarm
event will be triggered either the sampled value exceeds the
Rising Threshold
or is under the
Falling Threshold. By default, the Alarm Type is all.
owner-name
—— The owner of the entry, ranging from 1 to 16 characters. By
default, it is monitor.
interval
—— The alarm interval time, ranging from 10 to 3600 in seconds. By
default, it is 1800.
Command Mode
Global Configuration Mode
Privilege Requirement
Only Admin level users have access to these commands.
Example
Configure rmon alarm entries 1-3 binding with statistics entry 2, the owners
as owner1 and the alarm intervals as 100 seconds:
T1700G-28TQ(config)#rmon alarm 1-3 stats-index 2 owner owner1
interval 100
29.16 rmon statistics
Description
The rmon statistics command is used to configure the entries of
SNMP-RMON statistics. To delete the corresponding entry, please use no
rmon statistics command. The maximum supported entries are 1000.
Syntax
rmon statistics
index
interface { gigabitEthernet
port
| ten-gigabitEthernet
port
} [ owner
owner-name
] [ status { underCreation | valid }]
no rmon statistics
index
279