Nilfisk SH AUTO 5M [25/33] Auto booster

Nilfisk SH AUTO 5M [25/33] Auto booster
25
AUTO BOOSTER
Original Instructions
5.2 Hour counters
+
-
Day Week Month Year Winter
Water soften-
ing unit (op-
tion)
Check the level of salt tablets. If necessary
refi ll with salt tablets above the water level
in the brine tank.
x
Water soften-
ing unit (op-
tion)
Empty the brine tank and clean it.
x
Water soften-
ing unit (op-
tion)
Check the setting of the timer. Adjust if
necessary (see section 4.1.7). x
Water fi lter Clean the water fi lter of the water break
tank (see section 5.4) and the by-pass
lter.
x
Fuel fi lter Replace fuel fi lter (see section 5.6). x
Lance holder Check the lance holder for foreign bodies.
If necessary, dismount it by loosening 4
bolts.
x
Frost protec-
tion
Check that the heating unit starts in the
machine and that water is running through
the lance when the temperature drops
below the preset temperature.
x
Drain Check the drain of the washing place. x
Outdoor ther-
mostat
Clean the outdoor thermostat at the bot-
tom of the front door with a dry cloth.
x
Locks Lubricate locks with acid-free oil. x
5.1 Coin selector See section 4.1.5.
Your AUTO BOOSTER features built-in hour counters that keep
track of the number of working hours on your machine.
Change of digital readout - press the potentiometer.

Содержание

Скачать