6.2 Error messages
If your AUTO BOOSTER does not heat the water although heating has been chosen for the actual pro-
gram step, the reason may be that the fuel container is empty or that one of the overheat melting fuses
has blown/cut out. The two fuses are located at the top of the boiler and MUST ONLY be exchanged by
an Nilfi sk-ALTO service technician.
Error Message Reason Action
Illegal sensor comb. > Lack of water Check your water supply
– open?, suffi cient pressure?
Check and clean inlet fi lter,
(see sect. 5.4).
> Defective or mal-adjusted Call Nilfi sk-ALTO service.
ow sensor
No fl ame detected > No fl ame is detected when it Check your fuel supply,
should be present and refi ll is necessary.
> Fuel fi lter clogged Call Nilfi sk -ALTO service.
> Fuel container empty Refi ll with fuel.
> Flame sensor soothed or Call Nilfi sk -ALTO service.
defective
Illegal fl ame detected > Flame detected when it should Flame sensor not mounted
NOT be present in place. Mount sensor.
> Flame sensor defective Call Nilfi sk -ALTO service
Pump oil level low > Shortage of oil in high Top up with oil.
pressure pump
Water level low > Lack of water in water tank Check your water supply
– open?, suffi cient pressure?
Check and clean inlet fi lter,
(see sect. 5.4).
Inverter error > Cutting out of motor Check of fan.
protection or thermal current Check load of motor.
in motor Check input voltage.
Each time a fault is present, a counter will show the number of times the fault has been registered.