Nilfisk SH AUTO 5M [26/33] Auto booster

Nilfisk SH AUTO 5M [26/33] Auto booster
26
AUTO BOOSTER
Original Instructions
5.3 Oil Your AUTO BOOSTER is equipped with an electronic “oil sensor”,
which monitors the level of lubricant oil in the high-pressure pump. If
the oil level (by malfunction or excessive wear) should drop to a low
level, the pump will stop and the display shows "Pump oil level low".
Topping up the oil cup of the pump will be possible, but you should
send for a Nilfi sk-ALTO service technician as soon as possible to
disclose the cause of the oil loss.
+
-
Waste oil and oil sludge must be removed as laid down in the
instructions.
PROTECT THE ENVIRON-
MENT
5.4 Water lter To avoid debris entering the water break tank, water fi lters are fi tted
at the water inlet of the water break tank and at the by-pass re-
turn. Depending on the purity of the water, this fi lter will have to be
cleaned at regular intervals.
The fi lter can be removed by unscrewing the union nut/container(1).
If the fi lter in the water inlet is clogged up by impurities, the ma-
chine will stop because of water shortage. The display will show
"Water level low" "E10".
If the fi lter (2) in the by-pass return is clogged up, the water will
overfl ow where the lance is stored on the machine (14).
Do not forget to turn off the water before cleaning the fi lter.