Daikin EWYQ180DAYN [30/524] Technical specifications for options ewyq230 250dayn

Daikin EWYQ230DAYN [30/524] Technical specifications for options ewyq230 250dayn
General Outline ESIE06-05
1–18 Part 1 – System Outline
3
11
4
5
1.11 Technical Specifications for options: EWYQ230-250DAYN
Technical
specifications
The table below contains the technical specifications for the options of the EWYQ230~250DAYN.
Technical specifications options
OPSP
Units EWYQ230DAYN* EWYQ250DAYN*
Weight Additional machine weight kg 250 250
Additional operation weight kg 271 271
Additional gross weight kg 250 250
Pump Type
Single-stage-in-line-pumps Single-stage-in-line-pumps
Quantity 1 1
Model TP65-260/2 TP65-260/2
Nominal Static Height Unit Cooling kPa 143 129
Hydraulic components Additional unit water volume l 21 21
Expansion vessel l 50
Pre-charge pressure exp. vessel bar 1,5
Safety valve bar 3
OPSP + OPBT
Units EWYQ230DAYN* EWYQ250DAYN*
Weight Additional machine weight kg 300 300
Additional operation weight kg 511 511
Additional gross weight kg 300 300
Pump Type
Single-stage-in-line-pumps Single-stage-in-line-pumps
Quantity 1 1
Model TP65-260/2 TP65-260/2
Nominal Static Height Unit Cooling kPa 143 129
Hydraulic components Buffer tank l 190 190
Additional unit water volume l 211 211
Expansion vessel l 50
Pre-charge pressure exp. vessel bar 1,5
Safety valve bar 3
OPHP
Units EWYQ230DAYN* EWYQ250DAYN*
Pump Type
Single-stage-in-line-pumps Single-stage-in-line-pumps
Quantity 1 1
Model TP65-410/2 TP65-410/2
Nominal Static Height Unit kPa 292 280