Daikin RXQ34MAY1 [164/344] Part 6 troubleshooting

Daikin RXQ36MAY1 [164/344] Part 6 troubleshooting
Si39-501
Troubleshooting 153
Part 6
Part 6Part 6
Part 6
Troubleshooting
TroubleshootingTroubleshooting
Troubleshooting
1. Symptom-based Troubleshooting .......................................................156
2. Troubleshooting by Remote Controller ...............................................159
2.1 The INSPECTION / TEST Button.........................................................159
2.2 Self-diagnosis by Wired Remote Controller .........................................160
2.3 Self-diagnosis by Wireless Remote Controller .....................................161
2.4 Operation of The Remote Controllers Inspection /
Test Operation Button ..........................................................................164
2.5 Remote Controller Service Mode .........................................................165
2.6 Remote Controller Self-Diagnosis Function .........................................167
3. Troubleshooting by Indication on the Remote Controller ....................172
3.1 A0 Indoor Unit: Error of External Protection Device ...........................172
3.2 A1 Indoor Unit: PC Board Defect.........................................................173
3.3 A3 Indoor Unit: Malfunction of
Drain Level Control System (S1L)........................................................174
3.4 A6 Indoor Unit: Fan Motor (M1F) Lock, Overload...............................176
3.5 A7 Indoor Unit: Malfunction of Swing Flap Motor (MA) .......................177
3.6 A9 Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (20E) ........................................................179
3.7 AF Indoor Unit: Drain Level above Limit..............................................181
3.8 AJ Indoor Unit: Malfunction of Capacity Determination Device ..........182
3.9 C4 Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................183
3.10 C5 Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........184
3.11 C9 Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........185
3.12 CJ Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller ................................................................................186
3.13 E1 Outdoor Unit: PC Board Defect ......................................................187
3.14 E3 Outdoor Unit: Actuation of High Pressure Switch ..........................188
3.15 E4 Outdoor Unit: Actuation of Low Pressure Sensor ..........................189
3.16 E5 Outdoor Unit: Compressor Motor Lock ..........................................190
3.17 E6 Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............191
3.18 E7 Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................192
3.19 E9 Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................194
3.20 F3 Outdoor Unit: Abnormal Discharge Pipe Temperature ..................196
3.21 F6 Refrigerant Overcharged ...............................................................197
3.22 H7 Abnormal Outdoor Fan Motor Signal .............................................198
3.23 H9 Outdoor Unit: Malfunction of Thermistor for
Outdoor Air (R1T).................................................................................199
3.24 J2 Current Sensor Malfunction...........................................................200
3.25 J3 Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31~33T) .....................................................................................201
3.26 J5 Outdoor Unit: Malfunction of Thermistor (R2T) for
Suction Pipe .........................................................................................202