Daikin REYQ48MY1B [152/312] Part 6 troubleshooting

Daikin FXNQ50MVE [152/312] Part 6 troubleshooting
Si39-302
Troubleshooting 141
Part 6
Part 6Part 6
Part 6
Troubleshooting
TroubleshootingTroubleshooting
Troubleshooting
1. Troubleshooting by Remote Controller ...............................................143
1.1 The INSPECTION / TEST Button.........................................................143
1.2 Self-diagnosis by Wired Remote Controller .........................................144
1.3 Self-diagnosis by Wireless Remote Controller .....................................145
1.4 Operation of The Remote Controller’s Inspection /
Test Operation Button ..........................................................................148
1.5 Remote Controller Service Mode .........................................................149
1.6 Remote Controller Self-Diagnosis Function .........................................151
2. Troubleshooting by Indication on the Remote Controller ....................156
2.1 A0” Indoor Unit: Error of External Protection Device ...........................156
2.2 A1” Indoor Unit: PC Board Defect.........................................................157
2.3 A3” Indoor Unit: Malfunction of Drain Level Control System (33H) ......158
2.4 A6” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................160
2.5 A7Indoor Unit: Malfunction of Swing Flap Motor (MA) .......................161
2.6 A9” Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (20E) ........................................................163
2.7 AF” Indoor Unit: Drain Level above Limit..............................................165
2.8 AJ” Indoor Unit: Malfunction of Capacity Determination Device ..........166
2.9 C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................167
2.10 C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........168
2.11 C9Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........169
2.12 CJ” Indoor Unit: Malfunction of Thermostat
Sensor in Remote Controller ................................................................170
2.13 E1 Outdoor Unit: PC Board Defect ......................................................171
2.14 E3” Outdoor Unit: Actuation of High Pressure Switch ..........................172
2.15 E4” Outdoor Unit: Actuation of Low Pressure Sensor ..........................173
2.16 E5” Compressor Motor Lock ................................................................174
2.17 E6” Compressor Motor Overcurrent/Lock ............................................175
2.18 E7” Malfunction of Outdoor Unit Fan Motor..........................................176
2.19 E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................178
2.20 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................180
2.21 F6Refrigerant Overcharged ...............................................................181
2.22 H7Abnormal Outdoor Fan Motor Signal .............................................182
2.23 H9” Outdoor Unit: Malfunction of Thermistor for Outdoor Air (R1T).....183
2.24 J2” Current Sensor Malfunction...........................................................184
2.25 J3” Outdoor Unit: Malfunction of Discharge
Pipe Thermistor (R31~33T)..................................................................185
2.26 J5” Outdoor Unit: Malfunction of Thermistor (R2T) for Suction Pipe ...186
2.27 J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger ..............................................................187
2.28 J9” Malfunction of Receiver Gas Pipe Thermistor (R5T).....................188
2.29 JA Outdoor Unit: Malfunction of Discharge Pipe Pressure Sensor.....189
2.30 JCOutdoor Unit: Malfunction of Suction Pipe Pressure Sensor .........190